[Automatic]Z-Axis Linear Ball

Brand :
MISUMI
Caution
- Please confirm the suitable power supply for each motor option.
5-Phase Stepping Motor with Brake (MA) works with single-phase AC100-120V.
α-Step Motor (PA) works with DC24V.
AC Servo Motor (U) works with single-phase or three-phase AC200-230V. - Please check the content on our website as the PDF does not contain the most up-to-date information.
- Delivery times for some of our products may be delayed as national government authorities have imposed limit of capacity at our production sites.
Product Description
Z-axis type with high rigidity, compact width, and overall length that saves space.

[ ! ]The drawing is for the L (left) Cover Positon Type.
[ M ]Material: SUS440C Equivalent
[ S ]Surface Treatment: Electroless Nickel Plating
[ A ]Accessory: ZMSG413/513: SCB3-10, 4 pcs.
[ S ]Surface Treatment: Electroless Nickel Plating
[ A ]Accessory: ZMSG413/513: SCB3-10, 4 pcs.
ZMSG615: SCB4-12, 4 pcs.
ZMSG715: SCB3-12, 4 pcs.
ZMSG715: SCB3-12, 4 pcs.
More Information
■Common Specifications
*1 Stage travel per one pulse.
[ ! ]Accuracy specifications are for single axis (horizontal orientation) configuration.
| Feed Screw | Ball Screw Ø6, Lead 1 |
| Guide | Linear Ball Guide |
| Resolution *1 | 2μm/Pulse (Full) 1μm/Pulse (Half) |
| Positioning Repeatability | Within ±0.5μm |
| Load Capacity | 49N |
| Lost Motion | 1μm or less |
| Backlash | 0.5μm or less |
| Parallelism | 15μm or less |
[ ! ]Accuracy specifications are for single axis (horizontal orientation) configuration.
■Motor/Cable Application Table
[ ! ]For the cable for C, F or G, see MSCB□ on P.1-2014-3
■Max. Speed
[ ! ]Note that the speed and positioning time will vary depending on the usage conditions.
The values shown here are MISUMI’s reference values. Operation at these values is not guaranteed.
| Motor | Cable |
| C,D,E | N (Not Provided) |
| MA | M |
| PA | P |
| UA | U |
■Max. Speed
| Motor | (mm/sec) | Motor | (mm/sec) |
| C | 10 | MA | 10 |
| D | 25 | PA | 30 |
| E | 20 | UA | 50 |
The values shown here are MISUMI’s reference values. Operation at these values is not guaranteed.