Rubber Heaters-Square Type/With Thermostat

Brand :
MISUMI
Caution
Product Description
This is a rubber heater, square thermostat type. [Maximum Operating Temperature]220°C

■Lead Wire Retaining Sheet Dimensions
Dimensions in ( ) are reference values.
| Type | Current Value A | C | D | E |
| MRHSSB | Less than 5A | (25) | (40) | (33) |
| 5 A to less than 8 A | (40) | (40) | (18) | |
| 8A~10A | (40) | (100) | (18) |
[ M ] Material :
Heater : Silicon Rubber
Lead Wire: Nickel (Ni)
Lead Wire Film: fluoropolymer
Maximum Operation Temperature: 220°C
- Thermostats
Heater: Ceramic (Steatite Type)
Cap: Aluminum
Bimetal: Disk Bimetal
More Information
■Features
•The bimetal thermostat with automatic recovery system prevents overheating of rubber heaters.
(Features of Thermostats)
Principle of Operation: Bimetal Non-energizing Type Single Pole Single Throw Operation Temperature One Point Fixed Type
Operating Method: OFF when temperature rises, and ON when temperature drops
(Electric Rating)
Resistance Load AC125V/10A AC250V/5.0A (Minimum Current:0.1A)
(Contact Resistance)
50mΩ or less according to minute current ohmmeter (DC6V/0.1A) (initial value)
(Insulation Resistance)
10MΩ or more with DC500V mega in the charge part and non-charge part
(Insulation Resistance)
AC1500V/min or AC1800V/sec in the charge part and non-charge part (Leakage current: 10mA)
(ON/OFF life span)
The thermal ON / OFF operation is done approx. 10,000 times or less at the load of rated current and voltage.
Insulation resistance: 50M ; Contact resistance: 100m or less
•The bimetal thermostat with automatic recovery system prevents overheating of rubber heaters.
(Features of Thermostats)
Principle of Operation: Bimetal Non-energizing Type Single Pole Single Throw Operation Temperature One Point Fixed Type
Operating Method: OFF when temperature rises, and ON when temperature drops
(Electric Rating)
Resistance Load AC125V/10A AC250V/5.0A (Minimum Current:0.1A)
(Contact Resistance)
50mΩ or less according to minute current ohmmeter (DC6V/0.1A) (initial value)
(Insulation Resistance)
10MΩ or more with DC500V mega in the charge part and non-charge part
(Insulation Resistance)
AC1500V/min or AC1800V/sec in the charge part and non-charge part (Leakage current: 10mA)
(ON/OFF life span)
The thermal ON / OFF operation is done approx. 10,000 times or less at the load of rated current and voltage.
Insulation resistance: 50M ; Contact resistance: 100m or less
■Mounting Method
Apply Rubber Heater (left page) and attach to the heated object.
Apply Rubber Heater (left page) and attach to the heated object.
■Precautions for Use
[ ! ] A thermostat should not be used for temperature adjustment. Please use it as overheat protector.
[ ! ] Do not apply force to thermostat.
[ ! ] There are temperature gaps (about 10~40°C) between thermostat operating temperature and heater surface temperature, and between thermostat and heated object. Please check before actual use.
[ ! ] A part of upper terminal of thermostat is exposed. Please pay attention to short circuit.
[ ! ] Do not use it in inflammable atmospheres.
[ ! ] To avoid burn injury, do not touch the heater when the power supply is on or immediately after the use.
[ ! ] A thermostat should not be used for temperature adjustment. Please use it as overheat protector.
[ ! ] Do not apply force to thermostat.
[ ! ] There are temperature gaps (about 10~40°C) between thermostat operating temperature and heater surface temperature, and between thermostat and heated object. Please check before actual use.
[ ! ] A part of upper terminal of thermostat is exposed. Please pay attention to short circuit.
[ ! ] Do not use it in inflammable atmospheres.
[ ! ] To avoid burn injury, do not touch the heater when the power supply is on or immediately after the use.