XS2 T-joint Adapter

Brand :
MISUMI
Caution
Product Description
XS2 connector designed with sensor usage in mind

● A compact, T-joint model waterproof connector for sensors.
● It is possible to carry out bundling, branching and daisy chain connection in the middle of the cable.
● It has an IP67 class waterproof property and is suitable for connecting to a sensor cable that is exposed to severe environments.

·Core numbers other than 4-core are not in production.
·The current model is only DC. AC is not in production.
Specifications

| Model | Type | Power Supply Identification | Number of Cores | Weight g |
| XS2R-D422-1 | Bundling (Female - Male - Female) | DC | 4 | 16.2 |
| XS2R-D422-5 | 16.2 | |||
| XS2R-D424-1 | Daisy Chain (Female - Female - Male) | 16.0 |
Material / Finish
| Item | Materials | Finish |
|---|---|---|
| Contact | Brass | Nickel Base Gold Plating (0.4 μm) |
| Screw Part | Brass | Nickel-plated |
| Cap | PBT Resin | UL94V-0, Black |
| Cable Clamp | Polyamide Resin | UL94V-0, White |
| Lock Spring | LCP Resin | — |
| Waterproof Bushing | Rubber | — |
| Cover | PBT Resin | UL94V-0, Black |
| O-Ring | Rubber | — |
| Waterproof Cap | Brass | Nickel-plated |
Specifications
| Item | Characteristics |
|---|---|
| Rated Current | 3 A |
| Rated Voltage | For DC: 125 VDC, for AC: 250 VAC |
| Contact Resistance | 40 mΩ or less (20 mV or less, at 100 mA or less) |
| Insulation Resistance | 1,000 MΩ or more (at 500 VDC) |
| Withstand Voltage | 1,500 VAC, 1 minute (Leakage Current of 1 mA or less) |
| Protective Structure | IP67 (IEC529) |
| Insertion and Removal Durability | 200 times or more |
| Assembly Part Fixing Strength | Tension: 98 N (10 kgf) / 15 s |
| Rotation: 0.98 N・m (10 kgf・cm) / 15 s | |
| Cable Retention Force | 98 N (10 kgf) / 15 s |
| Operating Temperature Range | -25 ~ +70°C |
Compatible Wire Size
| Wiring Method | Cable Finished Outer Diameter | AWG Size | Conductor Cross-sectional Area |
|---|---|---|---|
| Screw Method | φ5 mm ~ φ6 mm | 24 ~ 18 | 0.18 mm2 ~ 0.75 mm2 |
| Soldering Method | 24 ~ 20 | 0.18 mm2 ~ 0.5 mm2 |
Contact Arrangement Diagram
Cable End Treatment Method