Commercial MATE-N-LOK Contact

Brand :
MISUMI
Caution
Product Description
Contact with excellent continuity / reliability when punching. 1 pack contains 100 pieces

● Contact to be incorporated into commercial MATE-N-LOK Connectors. Compatible electric wire can be connected up to AWG24-14.
● Manufacturer: Tyco Electronics

· Quantity: 100 pcs. / pack. Please note.
· Crimping by incorporating a crimp die to the special tool (Pro-crimper).
· It cannot be incorporated into other products.
Specifications

1 Pack Unit 100-piece Pack
| Model Number | Compatible Wire | Conductor Section Area (mm2) | Insulation OD (Maximum) | Type | Compatible Crimping Dies | Weight (g) |
| AWG | ||||||
| 60618-1 | 24 ~ 18 | 0.20 ~ 0.89 | 2.5 | Male (Pin) | 90574-2 | 0.3 |
| 60620-1 | 20 ~ 14 | 0.5 ~ 2.27 | 3.3 | 90575-2 | 0.4 | |
| 60617-1 | 24 ~ 18 | 0.20 ~ 0.89 | 2.5 | Female (Socket) | 90574-2 | 0.4 |
| 60619-1 | 20 ~ 14 | 0.5 ~ 2.27 | 3.3 | 90575-2 | 0.4 |
Features
● Commercial MATE-N-LOK Connectors are compact, lightweight nylon connectors with excellent impact and vibration resistance. They are widely used in applications such as home appliances, office machinery, motor vehicles, FA machinery and other electronic devices.● Because the lock mechanism is attached after coupling, the structure prevents the counterpart connector from disconnecting due to vibration.
● Commercial MATE-N-LOK Connectors have acquired both UL and CSA certification, meaning the performance quality of both standards provides a high level of assurance for use.
● The Pro Crimper, a manual crimping tool for nylon connector crimping, can also be used simply by die replacement.
● UL No.E28476
Compatible Wire Size
| AWG | Conductor Section Area mm2 | Sheath Outer Diameter φ (mm) | |
|---|---|---|---|
| Size | 24 ~ 14 | 0.2 ~ 2.27 | 1.9 ~ 3.3 |
Specifications
| Item | Contents |
|---|---|
| Rated Current | See table below |
| Rated Voltage | 250 VAC or less |
| Withstand Voltage | 1,500 VAC / 1 minute |
| Insulation Resistance | 500 MΩ or more |
| Contact Resistance | See table below |
| Operating Temperature Range | +105°C or less |
| Thermal Shock | -55°C ~ +85°C |
| Temperature / Humidity Cycling | 10°C ~ 65°C by 90 ~ 95 RH |
| Corrosion | 5% by 48 Hours (Salt Mist) |
| Vibration | 1.52 mm for all processes 10 - 55 - 10 |
| Physical Impact | 18 shocks, 50 Gs sawtooth in 10 milliseconds |
| Durability | Coupling and Detaching 50 Times |
Allowable Current and Contact Resistance
| Wire Size (AWG) | Allowable Current (A) | Contact Resistance (mΩ or less) |
|---|---|---|
| 24 | 1.5 | 3.50 |
| 22 | 3 | 3.50 |
| 20 | 4.5 | 3.00 |
| 18 | 6 | 3.00 |
| 16 | 8 | 2.75 |
| 14 | 10 | 2.75 |
Material / Finish
| Item | Materials | Finish |
|---|---|---|
| Housing | Nylon | UL94V-2 (Natural Color) |
| Contact | Brass | Tin-plated |
Connector / Wire Selection Guidelines
● The thicker the wire, the less the current is reduced due to internal resistance, allowing higher current to be supported. Moreover, because the resistance is decreased by using a thick wire, it's possible to reduce the generation of heat. In addition, the wire also has a role in expelling heat from inside the connector.● Connectors generally have a great number of circuits (number of cores), so the carried current becomes reduced. Also, the higher the ambient temperature, the more the carried current will be reduced. (See graph)

About Coupling