Pilot kick type 2-port solenoid valve general-purpose valve ADK11/ADK12 series

Caution
- The product images are representative only. Specifications may vary by part number, including shape and color.
Product Description
Pilot kick type 2-port solenoid valve.
[Features]
· General-purpose valve series for controlling various types of fluids.
· Because it is reliable, high quality, rich in variation and options, it surely enhances high performance of various facilities and equipment.
· By combining body materials and sealants, it can be used for a wide variety of fluids.
· NC (normally closed, open when energized) type, NO (normally open, closed when energized) type
· Connection port diameter: Rc1/4 to Rc1, G1/2, G3/4, NPT3/4
· Diaphragm type drive
Pilot Kick Type 2-Port Solenoid Valve (General-Purpose Valve) ADK11/12 Series Specifications
Product Specification
| Items | Standard Specifications | Optional Specifications |
|---|---|---|
| Operating fluid | Air / low vacuum (1.33 x 103 Pa (abs)) / Water / Kerosene / Oil (50 mm2/s or less) | Warm water |
| Operating pressure differential range MPa | 0 to 1.0 (It varies depending on the type, so please refer to the maximum operating pressure differential per model.) | |
| Maximum operating pressure MPa | 2 | |
| Pressure resistance (at water pressure) MPa | 4 | |
| Fluid temperature (Note 1)°C | -10 to 60 | -10 to 90 |
| Ambient temperature°C | -10 to 60 | |
| Heat-resistant class | Class 130 (B) | Class 180 (H) |
| Environment | No Corrosive or Explosive Gases in Surroundings | |
| Valve Structure | Pilot kick-type poppet structure, diaphragm drive | |
| Valve seat leakage (*2) cm3/min (ANR) | 1 or less (with air) | |
| Mounting posture | Free | |
| Body/Seal material | Bronze/Nitrile Rubber | Bronze/Ethylene propylene rubber |
*1: No freezing.
*2: However, it is the value when the pneumatic pressure is 0.02 to 1.0 MPa for ADK11 (NC (normally open) type), and when the pneumatic pressure is 0.02 to 0.6 MPa for ADK12 (NO (normally closed) type). If used at less than 0.02 MPa, the seal will become unstable.
Product Specification
| Model number | Items | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Connection port diameter | Orifice diameter (mm) | Minimum operating pressure difference (MPa) | Maximum operating pressure differential (MPa) | Rated Voltage | Apparent power (VA) | Power consumption (W) | Weight (kg) | ||||||||||
| Air | Water, kerosene | Oil (50 mm2/s) | During retaining | Starting | AC 50 Hz/60 Hz | DC | |||||||||||
| AC | DC | AC | DC | AC | DC | 50 Hz | 60 Hz | 50 Hz | 60 Hz | ||||||||
| NC (energized open) type | |||||||||||||||||
| ADK11-8A | Rc1/4 | 12 | 0 | 1 | 0.7 | 1 | 0.7 | 0.7 | 0.6 | 100 V AC 50/60 Hz*8 200 V AC 50/60 Hz*8 DC12V DC24V DC48V DC100V | 24 | 19 | 61 | 54 | 10/8 | 11*2 (10.4) | 0.65 |
| ADK11-10A | Rc3/8 | 12 | 0.65 | ||||||||||||||
| ADK11-15A | Rc1/2 | 16 | 0.6 | 0.6 | 0.6 | 0.5 | 25 | 21 | 84 | 75 | 10/8.5 | 14*3 [17] | 0.9 | ||||
| ADK11-20A | Rc3/4 | 23 | 1.0 | ||||||||||||||
| ADK11-25A | Rc1 | 28 | 1.4 | ||||||||||||||
| NO (closed when energized) type | |||||||||||||||||
| ADK12-15A | Rc1/2 | 16 | 0 | 0.6 | 0.6 | 0.6 | 0.6 | 0.5 | 0.5 | 30 | 25 | 180 | 150 | 13/11 | 14 | 1.0 | |
| ADK12-20A | Rc3/4 | 23 | 1.2 | ||||||||||||||
| ADK12-25A | Rc1 | 28 | 1.6 | ||||||||||||||
- *1: The above model number indicates up to the basic connection port diameter (Rc).
- *2: The values in ( ) indicate the power consumption when equipped with a DIN terminal box.
- *3: The values in [ ] indicate the power consumption for the diode built-in coil.
- *4: For the maximum operating pressure differential of the diode built-in coil, please refer to the DC column.
- *5: Please keep the voltage fluctuation within +/- 10% of the rated voltage.
- *6: If the pressure is 0.02 MPa or less, please consider the AB71 series.
- *7: When using in low vacuum, evacuate from the OUT port side.
- *8: 100 V AC (50/60 Hz) can also be used with 110 V AC (60 Hz). 200 V AC (50/60 Hz) can also be used with 220 V AC (60 Hz). Coil housings 5A, 5M, 5N, 5I, and 5J are excluded.
ADK11 Series Dimensions
· Grommet lead wire type
ADK11-8A, 10 A-*2C

Drawing
Note 1: The external dimensions are the same for connection port diameter G and NPT screws.
ADK11-15A, 20 A, 25 A-*2C

Drawing
Note 1: The external dimensions are the same for connection port diameter G and NPT screws.
Note 2: Dimensions in ( ) are for body material SUS
| Type number | A | B | C | D | E | F | G |
|---|---|---|---|---|---|---|---|
| ADK11-15A-02C | 71 | 27 (29) | 14.5 | 75.5 | 102 | 50 | Rc1/2 |
| ADK11-20A-02C | 80 | 32 (35) | 17.5 | 79 | 108.5 | 60 | Rc3/4 |
| ADK11-25A-02C | 90 | 41 (45) | 21.5 (22.5) | 84.5 | 118 (119) | 71 | Rc1 |
ADK12 Series Dimensions
· Open Frame Lead Wire Type
ADK12-15A, 20 A, 25 A-*3 A

Drawing
Note 1: The external dimensions are the same for connection port diameter G and NPT screws.
| Type number | A | B | C | D | E | F | G |
|---|---|---|---|---|---|---|---|
| ADK12-15A-03A | 71 | 27 (29) | 14.5 | 77 | 134.5 | 50 | Rc1/2 |
| ADK12-20A-03A | 80 | 32 (35) | 17.5 | 80.5 | 141 | 60 | Rc3/4 |
| ADK12-25A-03A | 90 | 41 (45) | 21.5 (22.5) | 86 | 150.5 (151.5) | 71 | Rc1 |