Pilot-kick type 2 port electromagnetic valve PKA series for air

Caution
- Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.
Product Description
2 port solenoid valve employing pilot kick system. Series provided respectively for compressed air, water and steam. Can operate from differential pressure 0 as it uses a pilot kick system.
Note: CAD data of this series is being revised. Please wait till the corrections are done.
Specifications of pilot kick type 2-port solenoid valve for air, PKA series
| Item | PKA-04-27 | PKA-06-27 | PKA-10-27 | PKA-12-27 | PKA-14-27 | PKA-20-25 | |
|---|---|---|---|---|---|---|---|
| Operating fluid | Air | ||||||
| Connection port diameter | Rc1/2 | Rc3/4 | Rc1 | 32 flange | 40 flange | 50 Flanges | |
| Orifice diameter mm | 15 | 20 | 25 | 35 | 40 | 50 | |
| C [dm^3/(s*bar)] | 20 | — | — | — | — | — | |
| b | 0.30 | — | — | — | — | — | |
| s (mm^2) | — | 128 | 220 | 404 | 552 | 883 | |
| Operating pressure difference MPa | 0 to 0.7 | 0 to 0.5 | |||||
| Pressure resistance (water pressure) MPa | 1.5 | 1.0 | |||||
| Fluid temperature °C | 5 to 60 | ||||||
| Ambient temperature (°C) | 0 to 65 | 0 to 45 | 0 to 40 | ||||
| Valve seat leakage cm^3/min | 1 or less, 400 or less for stainless steel (*1) | 2 or less (*1) | |||||
| Mounting orientation | Limited to the vertical posture with the coil area facing up. | ||||||
| Weight (kg) | 1.8 | 2.2 | 2.9 | 9 | 10 | 13 | |
| Electrical Specifications | |||||||
| Rated Voltage | 100 V AC 50/60 Hz, 200 V AC 50/60 Hz | ||||||
| Apparent power VA | When holding | 30 | 75 | 90 | |||
| At startup | 80 | 150 | 180 | ||||
| Power consumption W | 22 | 57 | 68 | ||||
| Heat-resistant class | Class 130 (B) | ||||||
*1: PKA-04 to 14 values are for pneumatic pressure of 0.05 to 0.7 MPa, and PKA-20 values are for pneumatic pressure of 0.05 to 0.5 MPa. With 0.05 MPa or less pressure, the seal will be unstable.
*2: The conversion between the effective cross-sectional area S and the sonic conductance C is S ≈ 5.0 × C.
Internal structure / parts list

Internal Structure
| Product number | Part name | Materials | |
|---|---|---|---|
| 1 | Coil | — | — |
| 2 | Core assembly | SUS405 or equivalent, SUS316L | Stainless steel |
| 3 | Shading coil | Cu (Ag) | Copper (Silver) |
| 4 | Plunger | Equivalent to SUS405 | Stainless steel |
| 5 | Gasket | Inorganic fiber (PTFE) | — (Polytetrafluoroethylene) |
| Product number | Part name | Materials | |
|---|---|---|---|
| 6 | Spring | SUS304 | Stainless steel |
| 7 | Main valve | C3604·NBR (SUS304, PTFE) | Brass / nitrile rubber (Stainless steel, polytetrafluoroethylene) |
| 8 | Body | CAC408 (SCS13) | Bronze casting (Stainless Steel Cast Iron) |
| 9 | Bolt | SWRM (SUS304) | Steel (stainless steel) |
The numbers in the parentheses are for stainless steel body materials.
Dimensions

PKA-04 to 10-27

PKA-12 to 20-27 (25)
* d indicates the connection port diameter (Refer to the above specifications.)
| Model | A | B | C | D | E | F | G | H |
|---|---|---|---|---|---|---|---|---|
| PKA-04-27 | 90 | 126 | 29 | 88 | 23 (27) | — | 60 | 49 |
| PKA-06-27 | 100 | 133 | 35 | 95 | 26 (29) | — | 60 | 49 |
| PKA-10-27 | 110 | 145 | 44 (46) | 107 | 30 (33) | — | 60 | 49 |
| PKA-12-27 | 170 | 180 | 135 | 128 | — | 100 | 84 | 66 |
| PKA-14-27 | 180 | 185 | 140 | 133 | — | 105 | 84 | 66 |
| PKA-20-25 | 180 | 205 | 155 | 155 | — | 120 | 84 | 66 |
The dimensions in the parentheses are for stainless steel body materials.