Indexing Plunger (Nose Lock Type) (NDX-L)

Brand :
IMAO
Caution
Product Description
A nose-lock type for holding the pin in its retracted position. Available in steel and stainless steel.
Drawing

Dimensional drawing of NDX-L, NDX-L-SUS (single nut)

Dimensional drawing of NDX-LW, NDX-LW-SUS (double nut)
Product Specification
Material
| Type | Main body | Knob | Coil spring | Nose |
|---|---|---|---|---|
| NDX-L NDX-LW | SUM22L Black oxide coating | polyamide Matte Black | SUS302WPA | SUM22L HRC58 to 62 |
| NDX-L-SUS NDX-LW-SUS | SUS303 | SUS420 HRC53 to 55 |
Specifications Table
| Size | d (-0.02 -0.04) | S | M | L1 | A | D | L | W1 | T1 | W | T | B | Load (N) Min. – Max. | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| NDX-L NDX-L-SUS NDX-LW NDX-LW-SUS | 10 | 5 | 5 | M10 x 1 | 17 | 1.3 | 21 | 47 | 13 | 7 | 17 | 5 | 2 | 5 to 12 |
| 12 | 6 | 6 | M12 × 1.5 | 20 | 1.8 | 25 | 56 | 14 | 8 | 19 | 6 | 3 | 6-14 | |
| 16 | 8 | 8 | M16 x 1.5 | 26 | 2.3 | 33 | 74 | 19 | 10 | 24 | 8 | 15-35 | ||
| 20 | 10 | 10 | M20 × 1.5 | 28 | 2.8 | 80 | 22 | 12 | 30 | 10 | 15-34 | |||
| Steel | stainless steel | ||||||
|---|---|---|---|---|---|---|---|
| Single nut | Double nut | Single nut | Double nut | ||||
| Part number | Weight (g) | Part number | Weight (g) | Part number | Weight (g) | Part number | Weight (g) |
| NDX10L | 19 | NDX10LW | 25 | NDX10L-SUS | 19 | NDX10LW-SUS | 25 |
| NDX12L | 28 | NDX12LW | 37 | NDX12L-SUS | 28 | NDX12LW-SUS | 37 |
| NDX16L | 68 | NDX16LW | 86 | NDX16L-SUS | 68 | NDX16LW-SUS | 86 |
| NDX20L | 107 | NDX20LW | 142 | NDX20L-SUS | 107 | NDX20LW-SUS | 142 |
Usage Example

Positioning is engaged by the nose.

Nose retracts when knob is pulled.

When the knob is rotated 90°, the nose locks in the rest position.
Product Feature Details

Features of the plunger
- Hand-operated indexing plunger where nose retracts when knob is pulled, making it easy to release positioning, and when hand is released, nose returns to its original position due to built-in spring.
- The nose lock type can be locked (fixed) in the retracted position by pulling the knob and rotating it 90 degrees.
Technical Information & Design Ideas
| Size | Allowable shear force (N) | |
|---|---|---|
| NDX-L NDX-L-SUS NDX-LW NDX-LW-SUS | 10 | 589 |
| 12 | 848 | |
| 16 | 1507 | |
| 20 | 2355 | |
Nose machine strength table
| Size | Recommended Chamfering Size | |
|---|---|---|
| NDX-L NDX-L-SUS NDX-LW NDX-LW-SUS | 10 | 60° chamfer depth 2.5 |
| 12 | 60° chamfer depth 3.5 | |
| 16 | ||
| 20 | ||
When using the indexing plunger fully threaded into the plate, chamfer the tapped hole on the plate side.