Urethane Tube for General Pneumatic Use (high pressure type) U1

Brand :
NITTA
Caution
Product Description
[Features]
· Can be used in a higher pressure range than U2 tubes.
· Since it uses ether-based polyurethane resin, there is less erosion and deterioration caused by moisture or mold under high temperature and high humidity conditions.
· Coil processing and welding/ heat welding are possible.
Product Specification
Metric size (Group 4)
| Part number | Outer diameter x inner diameter (mm) | Maximum operating pressure (MPa at 20°C) | Minimum bending radius (mm) | ● Weight (g/m) | Standard collar (color symbol) | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Black | White | Yellow | Blue | Green | Red | |||||
| BK | WH | YL | BU | GN | RE | |||||
| U1-4-4 × 2.5 | 4 × 2.5 | (Air) 1.2 (water) 0.9 | 10 | 9 | Applicable | Applicable | Applicable | Applicable | Applicable | Applicable |
| U1-4-6 × 4 | 6 × 4 | 15 | 19 | Applicable | Applicable | Applicable | Applicable | Applicable | Applicable | |
| U1-4-8 × 5 | 8 × 5 | 23 | 36 | Applicable | Applicable | Applicable | Applicable | Applicable | Applicable | |
| U1-4-10 x 6.5 | 10 x 6.5 | 30 | 53 | Applicable | - | - | - | - | - | |
| U1-4-12 × 8 | 12 × 8 | 35 | 73 | Applicable | - | - | - | - | - | |
Operating Fluids and Operating Temperature Range
| Operating fluid | Operating temperature range |
|---|---|
| Air | -40 to +80 degrees |
| Water | 0°C to +50°C |
· Standard size: 20 m, 100 m
· Negative pressure performance: -101.294 kPa
Product Feature Details
Relationship Between Operating Temperature and Maximum Operating Pressure
The maximum operating pressure varies depending on the operating temperature (atmospheric temperature). When using at temperatures other than room temperature, be sure to refer to the maximum operating pressure change rate shown in the graph on the right and use within that value.
●Note
Use outside the allowable range may cause accidents or premature failure, and Nitta cannot be held responsible in such cases. Please be careful.
●Note
Use outside the allowable range may cause accidents or premature failure, and Nitta cannot be held responsible in such cases. Please be careful.

Compatible Fittings

(*1) When used in combination with the Chemifit series, the clean type and general type are combined.
When using the product in a clean environment, pay attention to the decrease in clean level.
Cautions and Prohibitions
Usage Precautions
- When using water as a fluid, certain types of additives may cause the tube to deteriorate.
- When using water as a fluid, keep the surge pressure below the maximum operating pressure. Also, make sure it does not freeze.