XY-Axis Fixed Stage (Manual Stage)

Brand :
CHUOSEIKI
Caution
Product Description
Clampless XY-axis fixed stage that stays in place after position adjustment.
[Features]
· Clampless stage that stays in place after position adjustment.
· Special mechanism to prevent backlash.
· Patent obtained.
· Use hex wrench to adjust position.
· Virtually no clamp screws or other projections from the main stage body.
· Can be installed horizontally, vertically or upside-down (load capacity restriction depends on the installation orientation).
[Applications]
· Ideal for workpieces that must remain stationary after camera or sensor position adjustment.
XY Axis Fixed Stage (Manual) Details

XY Axis Fixed Stage (Manual) LD-1251FX images

XY Axis Fixed Stage (Manual) LD-2551FX images
XY Axis Fixed Stage (Manual) Specifications
| Product Number | LD-1251FX | LD-4051FX | LD-6051FX |
|---|---|---|---|
| Movement Direction | XY axis 2 directions | ||
| Stage Surface | 11.8 mm × 24.8 mm | 40 mm × 40 mm | 60 mm × 60 mm |
| Clamp Method | Clamp-less | ||
| Feed Method | Feed screw P = 0.5 mm | Feed screw P = 0.7 mm | |
| Travel Range | ±1.5 mm | ±3.5 mm | ±5.5 mm |
| Movement Amount: 1 Knob Rotation | Approx. 0.5 mm | Approx. 0.7 mm | |
| Movement Guide | Fitting | ||
| Degree of Parallelism | 0.075 mm | ||
| Load Resistance | 4.9 N (0.5 kgf) | 39.2 N (4 kgf) | 58.8 N (6 kgf) |
| Mass | 0.02 kg | 0.19 kg | 0.41 kg |
| Main Materials / Surface Treatment | Aluminum alloy / black satin anodized aluminum | ||
| Product Number | LD-2551FX |
|---|---|
| Movement Direction | XY axis 2 directions |
| Stage Height | 16 mm |
| Stage Surface | 25 mm × 25 mm |
| Clamp Method | Clamp-less |
| Feed Method | Feed Screw P = 0.5 mm |
| Travel Range | ±3 mm |
| Movement Guide | Fitting |
| Load Resistance | 4.9 N (0.5 kgf) |
| Mass | 0.04 kg |
| Main Materials | Aluminum alloy / black satin anodized aluminum |