Compact head amplifier-separated photoelectric sensor E3C

Brand :
OMRON
Caution
Product Description
Drawing
Sensor Section

Amplifier Unit Section

Product Specification
Rating / Performance
Sensor Section
| Items | Type | ||||||
|---|---|---|---|---|---|---|---|
| Model E3C-S10 | Model E3C-S20W | Model E3C-S50 | E3C-S30T E3C-S30W | E3C-1 | E3C-2 | ||
| Sensing method | Transmittance type | ||||||
| Sensing Distance | 100 mm | 200 mm | 500 mm | 300 mm | 1 m | 2 m | |
| Standard detected object | ⌀2 mm or larger opaque object | ⌀3 mm or larger opaque object | ⌀1.5 mm or larger opaque object | ⌀4 mm or larger opaque object | ⌀8 mm or larger opaque object | ||
| Direction angle | Emitter and Receiver: 10 to 60° each | Emitter and Receiver: 10 to 40° each | Emitter and Receiver: Each 3 to 20° | Emitter and Receiver: Each 3 to 15° | |||
| Light source (emission wavelength) | Infrared emitting diode (950 nm) | Infrared emitting diode (940 nm) | Infrared emitting diode (950 nm) | ||||
| Operating ambient illuminance | Light-receiving surface illuminance, incandescent lamp: 3,000 lx or less, sunlight: 10,000 lx or less | ||||||
| Ambient temperature range | Operation and storage: -25 to +70°C (no freezing or condensation) | ||||||
| Ambient humidity range | When operating/storing: 35 to 85% RH (no condensation) | ||||||
| Insulation resistance | 20 MΩ or more (500 V DC insulation resistance tester) | ||||||
| Withstand voltage | 500 V AC 50/60 Hz 1 min | ||||||
| Vibration (endurance) | 10 to 55 Hz, 1.5 mm double amplitude, 2 hours in each direction of X, Y, and Z | ||||||
| Shock (endurance) | 500 m/s2 in Each X, Y, Z Direction 3 times | ||||||
| Protective Structure | IEC standard IP64, indoors only | IEC standard IP50, indoors only | IEC standard IP64, indoors only | IEC standard IP60, indoors only | IEC standard IP66, indoors only | ||
| Connection method | Pre-wired type (standard cord length 2 m) | ||||||
| Weight (packed state) | Approx. 50 g | Approx. 24 g | Approx. 60 g | Approx. 120 g | |||
| Material | Case | polycarbonate | ABS | polycarbonate | Zinc die-cast | ||
| Lens section | polycarbonate | Acrylic | polycarbonate | ||||
| Mounting bracket | - | Steel | |||||
| Accessory | Instruction manual | Cross-head/Straight-slot screws M2 x 8, spring lock washer, plain washer, nut M2, instruction manual | Instruction manual | Cross-head/Straight-slot screws M2 x 8, spring lock washer, plain washer, nut M2, instruction manual | Mounting bracket (with screws), Instruction manual | Mounting bracket (with screws), Instruction manual | |
| Items | Type | ||||
|---|---|---|---|---|---|
| E3C-DS5W | E3C-DS10T | E3C-DS10 | E3C-LS3R | ||
| Sensing method | Diffuse reflection model | Convergent reflective Type | |||
| Sensing Distance | 50 mm (White Paper 100 x 100 mm) | 100 mm (White Paper 100 x 100 mm) | 100 mm (White Paper 50 x 50 mm) | 30+/-3 mm (White Paper 10 x 10 mm) | |
| Hysteresis | 20% or less of detection distance | 10% or less of detection distance | +/-3% or less of detection distance | ||
| Light source (emission wavelength) | Infrared emitting diode (950 nm) | Infrared emitting diode (950 nm) | Red light emitting diode (680 nm) | ||
| Operating ambient illuminance | Light-receiving surface illuminance, incandescent lamp: 3,000 lx or less, sunlight: 10,000 lx or less | ||||
| Ambient temperature range | Operation and storage: -25 to +70°C (no freezing or condensation) | ||||
| Ambient humidity range | When operating/storing: 35 to 85% RH (no condensation) | ||||
| Insulation resistance | 20 MΩ or more (500 V DC insulation resistance tester) | ||||
| Withstand voltage | 500 V AC 50/60 Hz 1 min | ||||
| Vibration (endurance) | 10 to 55 Hz, 1.5 mm double amplitude, 2 hours in each direction of X, Y, and Z | ||||
| Shock (endurance) | 500 m/s2 in Each X, Y, Z Direction 3 times | ||||
| Protective Structure | IEC standard IP50 (indoors only) | IEC standard IP64 (indoors only) | |||
| Connection method | Pre-wired type (standard cord length 2 m) | ||||
| Weight (packed state) | Approx. 50 g | Approximately 55 g | |||
| Material | Case | polycarbonate | |||
| Lens section | polycarbonate | ||||
| Accessory | Cross-head/Straight-slot screws M2 x 8, spring lock washer, plain washer, nut M2, instruction manual | Instruction manual | |||
Amplifier Unit Section
| Items | Type | |||
|---|---|---|---|---|
| E3C-JC4P | ||||
| Power supply voltage | 12 to 24 V DC +/- 10%, ripple (p-p) 1 V or less | |||
| Power consumption (current) | 40 mA or less | |||
| Control output | load power supply voltage: 24 V DC or less load current: 100 mA or less NPN open collector output type (residual voltage: 1 V or less) Light-ON/Dark-ON switch changeover type | |||
| Timer function | OFF delay 0/40 ms (switch changeover type) | |||
| Ambient temperature range | Operating: -10 to +55°C, Storage: -25 to +70°C (no freezing or condensation) | |||
| Ambient humidity range | Operating: 35 to 85% RH, Storage: 35 to 85% RH (no condensation) | |||
| Insulation resistance | 20 MΩ or more (500 V DC insulation resistance tester) | |||
| Withstand voltage | 1,000 V AC 50/60 Hz for 1 min | |||
| Vibration (endurance) | 10 to 55 Hz, 1.5 mm double amplitude, 2 hours in each direction of X, Y, and Z | |||
| Shock (endurance) | 300 m/s2 in Each X, Y, Z Direction 3 times | |||
| Protective Structure | IEC standard IP40 (indoors only) | |||
| Protection circuit | Power supply reverse connection protection, Output short circuit protection, Mutual interference prevention function | |||
| Response time | Operation and recovery: 1 ms or less each | |||
| Connection method | Terminal block input, pre-wired (standard cord length 2 m) | |||
| Weight (packed state) | Approx. 80 g | |||
| Material | Case | ABS | ||
| Mounting bracket | Steel | |||
| Accessory | Mounting bracket, Adjustment screwdriver, Caution label, Instruction manual | |||