Non-contact temperature sensor ES1

Caution
Product Description
Drawing
ES1-LP3-N/ES1-LP10-N Main Body

ES1-LW50-N/ES1-LW50L-N Main Body

(For ES1-LW50-N, there is no laser output port (6) or laser switch (7).)
ES1-LW100-N/ES1-LW100L-N Main Body

(For model ES1-LW100-N, there is no laser output port (6) or laser switch (7).)
ES1B

ES1C

Product Specification
ES1-N Rating / Performance
ES1-N
| Type | Without aiming laser | With aiming laser | |||||
|---|---|---|---|---|---|---|---|
| Part number | Model ES1-LP3-N | Model ES1-LP10-N | Model ES1-LW50-N | Model ES1-LW100-N | Model ES1-LW50L-N | Model ES1-LW100L-N | |
| Detection element | Thermopile | ||||||
| Lens | Silicone | ||||||
| Measurement wavelength | 8 to 14 μm | ||||||
| Output | USB output | Resolution: 0.1°C | |||||
| Current output | 4 to 20 mA / -50 to 500°C *1 Load impedance 250Ω or less Resolution 0.24μA | 4 to 20 mA / -50 to 1,000°C *1 Load impedance 250Ω or less Resolution 0.24μA | 4 to 20 mA / -50 to 500°C *1 Load impedance 250Ω or less Resolution 0.24μA | 4–20 mA / -50 to 1,000°C *1 Load impedance 250Ω or less Resolution 0.24μA | |||
| Power supply voltage | DC12–24 V / USB bus power (Only outputs other than current output are available with USB bus power only) | ||||||
| Allowable power supply voltage fluctuation | 95–105% of power supply voltage | ||||||
| Current Consumption | 30 mA or less (at 24 V DC) | · 30 mA or less (at 24 V DC, when the aiming laser is not in use) · 40 mA or less (at 24 V DC, when the aiming laser is in use) | |||||
| Cable length | 2 m ±5 cm | ||||||
| Measuring Accuracy | USB output · within ±(-8% rdg + 1)°C (measurement temperature: -50 to 0°C) · within ±1°C (measurement temperature: 0 to 200°C) · within ±0.5% rdg°C (200 to 500°C) Current output · Difference from USB output Within (±0.1% output range)°C | USB output · within ±(-8% rdg + 1)°C (measurement temperature: -50 to 0°C) · within ±1°C (measurement temperature: 0 to 200°C) · within ±0.5% rdg°C (200 to 1,000°C) Current output · Difference from USB output Within (±0.1% output range)°C | USB output · within ±(-8% rdg + 1)°C (measurement temperature: -50 to 0°C) · within ±1°C (measurement temperature: 0 to 200°C) · within ±0.5% rdg°C (200 to 500°C) Current output · Difference from USB output Within (±0.1% output range)°C | USB output · within ±(-8% rdg + 1)°C (measurement temperature: -50 to 0°C) · within ±1°C (measurement temperature: 0 to 200°C) · within ±0.5% rdg°C (200 to 1,000°C) Current output · Difference from USB output Within (±0.1% output range)°C | |||
| Repeatability | · Within 0.5°C | · Within 1°C (measurement temperature: -50 to 0°C) · Within 0.5°C (Measurement temperature: 0 to 500°C) · Within 1°C (Measurement temperature: 500 to 1,000°C) | · Within 0.5°C | · Within 1°C (measurement temperature: -50 to 0°C) · Within 0.5°C (Measurement temperature: 0 to 500°C) · Within 1°C (Measurement temperature: 500 to 1,000°C) | |||
| Temperature drift | · Within ±0.5°C/°C (measurement temperature: -50 to 0°C) · Within ±0.25°C/°C (Measurement temperature: 0 to 500°C) | · Within ±0.5°C/°C (measurement temperature: -50 to 0°C) · Within ±0.25°C/°C (Measurement temperature: 0 to 500°C) · Within ±0.5°C/°C (Measurement temperature: 500 to 1,000°C) | · Within ±0.5°C/°C (measurement temperature: -50 to 0°C) · Within ±0.25°C/°C (Measurement temperature: 0 to 500°C) | · Within ±0.5°C/°C (measurement temperature: -50 to 0°C) · Within ±0.25°C/°C (Measurement temperature: 0 to 500°C) · Within ±0.5°C/°C (Measurement temperature: 500 to 1,000°C) | |||
| Effects of electromagnetic interference*2 | Electromagnetic field electric discharge immunity | Within ±10°C (80 MHz to 1.0 GHz) | |||||
| Conducted noise immunity | Within ±10°C (150 kHz to 80 MHz) | ||||||
| Response time | Current output: 0.14s or less (95% response, when moving average is 1) | ||||||
| Reflection Rate | Factory default: 0.95 Can be changed to 0.100–1.999 using the configuration tool | ||||||
| Moving average function | Factory default: 10 Can be changed to 1–1,000 using the configuration tool | Factory default: 50 Configurable to 1 to 1,000 using the configuration tool | Factory default: 10 Configurable to 1 to 1,000 using the configuration tool | Factory default: 50 Configurable to 1 to 1,000 using the configuration tool | |||
| Operating temperature and humidity range | Temperature: 0 to 55°C, Humidity: 35 to 85% (no condensation) | ||||||
| Storage temperature range | -20 to 55°C (no condensation) | ||||||
| Vibration resistance | Malfunction | 10 to 55 Hz, 20 m/s2, 10 min in 3-axis directions | |||||
| Endurance | 10 to 55 Hz, 0.75 mm single amplitude, 2 hr in 3-axis directions | ||||||
| Protective structure | N/A | ||||||
| Applicable standards | CE, KC, FCC, RCM | ||||||
| - | IEC60825-1, PSC, FDA | ||||||
| External dimensions | W32 mm x H40 mm x L58 mm | W32 mm x H40 mm x L90.3 mm | W32 mm x H40 mm x L60.4 mm | W32 mm x H40 mm x L92.7 mm | |||
| Weight | Approx. 95 g | Approx. 115 g | Approx. 95 g | Approx. 115 g | |||
| Standard accessories | Instruction manual, mounting metal fitting, power/output cable (2 m), installation gauge | Instruction manual, mounting metal fitting, power/output cable (2 m) | |||||
*1. The default setting at shipment is 0 to +500°C. When using in the range of -50°C to +500°C or -50°C to +1,000°C, the range must be changed using ES1-TOOLS.
*2. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2). In that case, the measurement error will be ±10°C.
ES1B
| Items | Part number | |
|---|---|---|
| ES1B | ||
| Power supply voltage | 12 V DC, 24 V DC | |
| Allowable power supply voltage fluctuation | 90–110% of the power supply voltage | |
| Current Consumption | 20 mA or less | |
| Measurement Temperature Range | 10–70°C, 60–120°C, 115–165°C, 140–260°C | |
| Accuracy*1 | ±5°C*2 | ±2%PV or ±2°C, whichever is greater |
| ±10°C*2 | ±4%PV or ±4°C, whichever is greater | |
| ±30°C*2 | ±6%PV or ±6°C, whichever is greater | |
| ±40°C*2 | +/-8%PV or +/-8°C, whichever is greater | |
| Repeatability | ±1%PV or ±1°C, whichever is greater | |
| Temperature drift | 0.4°C/°C or less | |
| Effects of Electromagnetic Interference | Electric Field Strength Noise Immunity | Within +/-10°C (80-800MHz) |
| Within +/-30°C (800-1000MHz) | ||
| Conducted Disturbance Noise Immunity | Within +/-10°C | |
| Measurement Distance: Field of View Diameter | 1:1 typ. | |
| Measurement wavelength | 6.5 to 14.0 μm | |
| Light receiving element | Thermopile | |
| Response Speed | Approximately 300 ms for 63% response | |
| Output Impedance | 1 to 4 kΩ | |
| Operating temperature range | -25 to +70°C (no condensation or freezing) | |
| Permissible ambient humidity | Relative humidity 35 to 85% | |
| Vibration resistance (endurance) | 98 m/s2 10 to 55 Hz (X, Y, Z directions for 2 hours each) | |
| Impact Resistance (Endurance) | 300 m/s2 in Each X, Y, Z Direction 3 times | |
| Main Body Material | ABS Resin | |
| Protective structure | IP65 | |
| Applicable standards | CE marking*3 | |
| Weight | Approx. 120 g | |
| Lead | Compensating cable 3 m | |
| PVC insulation, heat resistant up to 70°C | ||
*1. When using K thermocouple characteristics and an emissivity of 0.98
*2. Temperature change from any reference temperature of the measurement target
Example: When corrected with 50°C as the reference temperature,
at 55°C, the accuracy is the greater of ±2% PV or ±2°C,
at 60°C, the accuracy is the greater of ±4% PV or ±4°C.
*3. EN61326-1: industrial electromagnetic environment (EN/IEC61326-1 Table 2)
ES1C
| Items | Part number | |
|---|---|---|
| ES1C | ||
| Power supply voltage | DC12-24V | |
| Allowable Voltage Fluctuation Range | 90% to 110% of rated voltage | |
| Current Consumption | 70 mA or less | |
| Measurement Temperature Range | 0 to 400°C | |
| Measuring Accuracy | 0–200°C: ±2°C 201–400°C: ±1% PV (emissivity 0.95) | |
| Effects of Electromagnetic Interference | Electric Field Strength Noise Immunity | ±10°C max |
| Conducted Disturbance Noise Immunity | ±10°C max | |
| Response time | 100 ms/90% | |
| Repeatability | ±1% of the reading | |
| Measurement wavelength | 8 to 14 μm | |
| Light receiving element | Thermopile | |
| Reflection Rate | 0.95 fixing | |
| Current output | DC 4–20 mA, load 250 Ω or less | |
| Ambient temperature range | During use: 0 to +70°C, during storage: -20 to +70°C (No freezing or condensation) | |
| Ambient humidity range | During use/storage: relative humidity 35–85% | |
| Vibration resistance (endurance) | 10 to 55 Hz, amplitude 1.5 mm, 2 hr in each direction of X, Y, and Z | |
| Weight | 180 g | |
| Protective structure | Equivalent to IP67 | |
| Applicable standards | CE marking* | |
*EN61326-1: industrial electromagnetic environment (EN/IEC61326-1 Table 2)
Parts List
| No. | Name |
|---|---|
| (1) | Lens |
| (2) | Screw Hole for Mounting Metal Fitting |
| (3) | Tripod Screw Hole |
| (4) | Power output connector |
| (5) | Micro USB connector |
| (6) | Laser output port |
| (7) | Laser Switch |
| (8) | Mounting gauge mounting hole |