Adapter KQ2N (Gasket Seal) One-Touch Fitting KQ2 Series

Caution
- See the catalog for details on materials and specifications.
- Product images may be representative images. Refer to the catalog for details.
Product Description
A one-touch fitting for connecting one-touch fittings and R female threads.
[Features]
· A compact and lightweight fitting with improved tube insertion/removal.
· Suitable for use with metric-size tubing and M connection threads. Four types available for use in different applications.
· Effective for piping in confined spaces. The body and thread part rotate, allowing for positioning.
[Applications]
· Use to connect tubing fittings and R female threads.
Adapter KQ2N (Gasket Seal) Specifications

Adapter KQ2N (Gasket Seal) dimensional drawing
| Applicable tube fitting size ød | Connection thread M | Model | H (width across flats) | L | A | M | Minimum hole diameter | Weight g |
|---|---|---|---|---|---|---|---|---|
| ø4 | M5 × 0.8 | KQ2N04-M5□ | 7 | 29.7 | 26.7 | 13.4 | 2.5 | 2.4 |
| ø6 | M5 × 0.8 | KQ2N06-M5□ | 7 | 29.7 | 26.7 | 13.4 | 2.5 | 2.6 |
*□: A (Brass), N (Brass + electroless nickel plating.)

Main part.
| Body | C3604, PBT, PP, SUS303 |
|---|---|
| Stud | C3604 (thread part), SUS303 (thread part) |
| Chuck | SUS304 |
| Guide | SUS304 |
| Release button | POM |
| Seal, O-ring | NBR |
| Gasket | SUS304, NBR |
Materials.
| Tube materials | FEP, PFA, nylon, soft nylon, polyurethane |
|---|---|
| Tube outer diameter | ø3.2, ø4, ø6 |
Applicable tube.
| Usable fluids | Air, water | |
|---|---|---|
| Operating pressure range | -100 kPa to 1 MPa | |
| Guaranteed proof pressure (at 23°C) | 3 MPa | |
| Ambient temperature and fluid temperature | -5 to 60°C, For water: 0 to 40°C (no freezing) | |
| Thread | Mounting section | JIS B0203 (tapered pipe thread) JIS B0205 (metric coarse thread) |
| Nut section | JIS B0205 (metric fine thread) | |
| Thread part seal | Sealing agent included | |
Specifications.
Product usage precautions
Note 1: Fittings without a thread portion and with all resin bodies are copper free specifications.
Note 2: The surge pressure must be under the maximum operating pressure.
Note 3: Do not use the fittings with a leak tester or for vacuum retention because they are not guaranteed for zero leakage.