5-Port Solenoid Valve, Plug-In Cassette Type, SQ1000 Series Valve

Caution
- Product images may be representative. Refer to the manufacturer's catalog for details.
Product Description
SMC Solenoid Valve.
[Features]
· Clip type one-touch fittings for easy replacement of fittings
· The connector entry direction can be changed with a single push
· 4 position, dual 3-port valve
· Built-in back pressure check valve
Plug-In Unit SQ1000 Series Specifications

Plug-in unit SQ1000 Series external appearance

The single-action fittings can be replaced without removing the valve

The connector entry direction can be changed with a single push
| Valve Specifications | Valve Construction | Metal Seal | Rubber Seal | |
|---|---|---|---|---|
| Fluid | Air | |||
| Maximum Operating Pressure | 0.7 MPa (high-pressure type *3: 1.0 MPa) | |||
| Minimum Operating Pressure | Single | 0.1 MPa | 0.15 MPa | |
| Double (double solenoid) | 0.1 MPa | 0.1 MPa | ||
| 3 position | 0.1 MPa | 0.2 MPa | ||
| 4 Position Type | - | 0.15 MPa | ||
| Ambient Temperature and Operating Fluid Temperature | -10 to 50°C *1 | |||
| Lubrication | Not required | |||
| Pilot Valve – Manual Operation | Push type / locking type (tool required) | |||
| Vibration-Resistance / Impact-Resistance *2 | 30/150 m/s2 | |||
| Enclosure | Dust-proof | |||
| Solenoid Specifications | Coil Rated Voltage | 12, 24 V DC | ||
| Allowable Voltage Fluctuation | ±10% of rated voltage | |||
| Coil Insulation Type | Class B or equivalent | |||
| Power Consumption (Current) | 24 V DC | DC 0.4 W (17 mA), DC 0.95 W (40 mA) *4 | ||
| 12 V DC | DC 0.4 W (34 mA), DC 0.95 W (80 mA) *4 | |||
*1: Use dry air when operating at low temperatures. No condensation.
*2: Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 2,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at right angles to the main valve and armature. (Initial value)
Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state).
*3: Metal-seal type only.
*4: Values for high-speed response type and high-pressure type.
Model
| Series | Switching Method | Sealing Method | Model | Flow Rate Characteristics *1 | Response Time [ms] *2 | Weight (g) | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 → 4/2 (P → A/B) | 4 → 5 (A → R1) | Standard (0.4 W) | High Speed Response (0.95 W) | ||||||||||
| C (dm3/ [s·bar]) | b | Cv | C (dm3/ [s·bar]) | b | Cv | ||||||||
| SQ1000 | 2 Position | Single | Metal Seal | SQ1130 | 0.62 | 0.10 | 0.14 | 0.63 | 0.11 | 0.14 | 26 or less | 12 or less | 80 |
| Rubber Seal | SQ1131 | 0.79 | 0.20 | 0.19 | 0.80 | 0.20 | 0.19 | 24 or less | 15 or less | 80 | |||
| Double | Metal Seal | SQ1230D | 0.62 | 0.10 | 0.14 | 0.63 | 0.11 | 0.14 | 13 or less | 10 or less | 95 | ||
| Rubber Seal | SQ1231D | 0.79 | 0.20 | 0.19 | 0.80 | 0.20 | 0.19 | 20 or less | 15 or less | 95 | |||
| 3 Position | Closed Center | Metal Seal | SQ1330 | 0.58 | 0.12 | 0.14 | 0.63 | 0.11 | 0.14 | 44 or less | 29 or less | 100 | |
| Rubber Seal | SQ1331 | 0.64 | 0.20 | 0.15 | 0.58 | 0.26 | 0.16 | 39 or less | 25 or less | 100 | |||
| Exhaust Center | Metal Seal | SQ1430 | 0.58 | 0.12 | 0.14 | 0.60 | 0.14 | 0.14 | 44 or less | 29 or less | 100 | ||
| Rubber Seal | SQ1431 | 0.64 | 0.20 | 0.15 | 0.80 | 0.20 | 0.19 | 39 or less | 25 or less | 100 | |||
| Pressure Center | Metal Seal | SQ1530 | 0.62 | 0.12 | 0.14 | 0.63 | 0.14 | 0.14 | 44 or less | 29 or less | 100 | ||
| Rubber Seal | SQ1531 | 0.79 | 0.21 | 0.19 | 0.59 | 0.20 | 0.14 | 39 or less | 25 or less | 100 | |||
| 4 Position | Dual 3-Port Valve | Rubber Seal | SQ1A31 SQ1B31 SQ1C31 | 0.59 | 0.28 | 0.15 | 0.59 | 0.28 | 0.15 | 27 or less | 14 or less | 95 | |
*1: Values for cylinder connection port diameter C6, CYL. → EXH. 2 → 3 (B → R2) is reduced approx. 30% compared to 4 → 5 (A → R1).
*2: Based on JIS B 8419:2010. (Value at supply pressure of 0.5 MPa and with light and surge voltage suppressor. The values may change depending on the pressure and air quality.)
Product JIS Symbol

JIS symbol for 2 position single

JIS symbol for 3 position closed center

JIS symbol for 4 position dual 3 port valve (B)
With/Without Manifold Block

Without manifold block external appearance
- When ordering together with manifolds
- When only valve is required

With manifold (built-in back pressure check valve) external appearance
- When adding stations
*Lead wire not included.
*The valve is a 4 port specification [5 (R1) and 3 (R2) are common]. As such, back pressure cannot be prevented within the same valve when using dual 3-port valves.
Manual Operation Method

Non-locking push type (tool required) external appearance

Locking type (tool required) external appearance
Precautions
- *When energizing valves for a long period of time, heat generated by the coil will cause the temperature to rise, decreasing valve performance, decreasing the lifespan and adversely affecting nearby peripheral equipment.
- *When energizing a valve continuously, be sure to use the standard type (0.4 W) at an ambient temperature of 40°C or less and pay attention to discharging heat.
- *Temperature increases are particularly high when simultaneously energizing 3 or more neighboring stations for a long-period continuously or when simultaneously energizing the A side and B side of a dual 3-port valve for an extended period.
- Be sure to read the individual product cautions before use.
- See the SMC catalog for product information other than that detailed above.