Suction Plate SP Series

Brand :
SMC
Caution
- Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details. - Refer to the manufacturer's catalog for specification and material details.
- The product images are representative only. Please refer to the manufacturer's catalog for shape details.
- CAD data is not available for some model numbers.
Product Description
[Features]
・ Compatible with adsorption and fixation of thin sheets, glass substrates, soft workpieces, etc.
There is no deformation of the workpiece during suction because it sucks through a large number of minute holes on the suction surface.
・ High processing accuracy.
・ Great holding force.
Drawing
Rectangle/SP1□30

SP1130/SP1230

SP1330/SP1430/SP1530/SP1630
Square/SP2□30

SP2130/SP2230

SP2330/SP2430/SP2530/SP2630
Product Specifications
| Part number | Rectangle | SP1130 | SP1230 | SP1330 | SP1430 | SP1530 | SP1630 |
|---|---|---|---|---|---|---|---|
| Square | SP2130 | SP2230 | SP2330 | SP2430 | SP2530 | SP2630 | |
| Flatness μm or less | 15 | 15 | 15 | 25 | 25 | 25 | |
| Parallelism µm or less | 30 | 30 | 30 | 40 | 40 | 40 | |
| Weight (kg) | Rectangle | 0.5 | 1.2 | 2.1 | 3.2 | 5.8 | 8 |
| Square | 0.4 | 1.0 | 1.8 | 2.9 | 5.3 | 7.4 | |
| Vacuum part | Size mm | □50 × 50 | □100 × 100 | □150 × 150 | □200 × 200 | □250 × 250 | □300 × 300 |
| Sintered body particle diameter mm | ⌀0.3 (sphere) | ||||||
| Opening Ratio | 15% or more | ||||||
| Materials | Stainless steel | ||||||
| Finish | Lapping | ||||||
| Body | Materials | Cast aluminum | |||||
| Surface Treatment | Chromate (excluding vacuum surface side and seat surface) | ||||||
| Finish | Grinding | ||||||
| Ambient temperature °C | 10 to 40 | ||||||
| Suction port Rc | 1/8 | ||||||
Part number display method

Product that supports changes in suction port position and element type (particle size)

- (1) It is a made-to-order specifications product with the change of the particle size of the element of the standard product and position the suction port on the side.
- (2) Refer to the table for the side port position dimensions. The back port is closed with a sunk-head plug.
- (3) The open area and pull force depending on the particle size of the element do not change .
Standard table
Rectangle/SP1□30

Square/SP2□30