3-port solenoid valve, Pilot type elastic seal, clean series 10-SYJ300 series

Caution
- Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details. - Refer to the manufacturer's catalog for specification and material details.
- The product images are representative only. Please refer to the manufacturer's catalog for shape details.
Product Description
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
Drawing
Direct piping type
Grommet (G), (H): 10-SYJ3□2M-□G/H□□-M3

Base Mounting Type (with Sub-Plate)
Grommet (G), (H): 10-SYJ3□4M-□G/H□□-M5

* [] is for AC
Product Specifications
Part number display method

*) When ordering a body ported type solenoid valve with a single unit, the manifold mounting screw and gasket are not included, so please order separately if necessary.
Specifications
| Operating fluid | Air | |
|---|---|---|
| Operating pressure range MPa | Internal Pilot Type | 0.15 to 0.7 |
| Ambient and operating fluid temperatures °C | -10 to +50 (No freezing.) | |
| *1) Response time ms (At 0.5 MPa) | 15 or less | |
| Maximum Operating Frequency Hz | 10 | |
| Manual (Manual Operation) | Non-locking push type, push-turn locking type screwdriver-operated type, push-turn locking manual-operation type | |
| Pilot Exhaust Method | Common exhaust type for main valve and pilot valve | |
| Lubrication | Not required | |
| Mounting orientation | Free | |
| *2) Impact resistance / vibration resistance m/s^2 | 150/30 | |
| Protective structure | Dust-proof (*M8 connector is IP65) | |
*Based on IEC60529.
*1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature of 20°C, at rated voltage, without surge voltage suppressor)
*2) Impact resistance: No malfunctions after testing under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunction when tested under 45 to 2,000 Hz 1 sweep, axial and perpendicular directions of the main valve / armature, energized and non-energized conditions. (Initial value)
Flow Rate Characteristics / Weight List
| Valve part number | Switching method | Pipe connection diameter | Flow rate characteristics | Effective Cross-Sectional Area mm^2 | ^*) Weight g | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1→2 (P→A) | 2→3 (A→R) | Grommet | L, M plug connector | M8 connector | |||||||||
| C [dm^3/(s*bar)] | b | Cv | C [dm^3/(s*bar)] | b | Cv | ||||||||
| Direct piping type | 10-SYJ312M | N.C. | M3 × 0.5 | — | — | — | — | — | — | 0.9 | 32 | 33 | 37 |
| 10-SYJ322M | N.O. | — | — | — | — | — | — | ||||||
| Base Mounting Type (with Sub-Plate) | 10-SYJ314M | N.C. | M5 × 0.8 | 0.41 | 0.18 | 0.086 | 0.35 | 0.33 | 0.086 | — | 53 (32) | 54 (33) | 58 (37) |
| 10-SYJ324M | N.O. | 0.36 | 0.31 | 0.089 | 0.36 | 0.31 | 0.089 | ||||||
*) Value for DC. For AC, add 1 g. Values in parentheses are values without sub-plates.