3-port solenoid valve, pilot type, elastic seal, clean series 10-SYJ700 series

Caution
- Refer to the manufacturer's catalog for specification and material details.
- The product images are representative only. Please refer to the manufacturer's catalog for shape details.
Product Description
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
Drawing
Direct piping type


* [] is for AC
Product Specifications
Part number display method

Specifications
| Operating fluid | Air | |
|---|---|---|
| Operating pressure range MPa | Internal Pilot Type | 0.15 to 0.7 |
| Ambient and operating fluid temperatures °C | -10 to +50 (No freezing.) | |
| ^*1) Response time ms (At 0.5 MPa) | 30 or less | |
| Maximum Operating Frequency Hz | 5 | |
| Manual (Manual Operation) | Non-locking push type, push-turn locking type screwdriver-operated type, push-turn locking manual-operation type | |
| Pilot Exhaust Method | Common exhaust type for main valve and pilot valve | |
| Lubrication | Not required | |
| Mounting orientation | Free | |
| ^*2) Impact resistance / vibration resistance m/s^2 | 150/30 | |
| Protective structure | Dust-proof (*DIN terminal and M8 connector are IP65) | |
*Based on IEC60529.
*1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature of 20°C, at rated voltage, without surge voltage suppressor)
*2) Impact resistance: No malfunctions after testing under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunction when tested under 45 to 2,000 Hz 1 sweep, axial and perpendicular directions of the main valve / armature, energized and non-energized conditions. (Initial value)
Flow Rate Characteristics / Weight List
| Valve part number | Switching method | Pipe connection diameter | Flow rate characteristics | ^*) Weight g | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1→2 (P→A) | 2→3 (A→R) | Grommet type | L, M plug connector | DIN terminal | M8 connector | ||||||||
| C [dm^3/(s*bar)] | b | Cv | C [dm^3/(s*bar)] | b | Cv | ||||||||
| Direct piping type | 10-SYJ712M | N.C. | 1/8 | 2.8 | 0.43 | 0.77 | 2.5 | 0.51 | 0.76 | 75 | 76 | 97 | 80 |
| 10-SYJ722M | N.O. | 2.7 | 0.38 | 0.72 | 2.4 | 0.42 | 0.69 | ||||||
| Base Mounting Type (with Sub-Plate) | 10-SYJ714M | N.C. | 1/8 | 2.9 | 0.32 | 0.71 | 2.7 | 0.34 | 0.69 | 135 (75) | 136 (76) | 157 (97) | 140 (80) |
| 10-SYJ724M | N.O. | 2.8 | 0.21 | 0.70 | 2.3 | 0.45 | 0.63 | ||||||
| 10-SYJ714M | N.C. | 1/4 | 3.0 | 0.31 | 0.74 | 2.6 | 0.33 | 0.66 | |||||
| 10-SYJ724M | N.O. | 2.7 | 0.31 | 0.68 | 2.3 | 0.48 | 0.64 | ||||||
*) Value for DC. For AC, add 3 g. Values in parentheses are values without sub-plates.