Factory Automation Cable, VCT531XX Series (Oil Resistant/Heat Resistant/Vibration Resistant)

Brand :
KURAMO ELECTRIC
Caution
Product Description
600 V UL/PSE standard power cable
Product Feature Details
[Features]
- Electrical Appliances and Materials Safety Act of Japan (7 cores or fewer) & UL, cUL AWM standard cable
- Oil resistant, heat resistance (105°C), vibration resistant
- Fine stranded conductor
- Sheath matte
[Applications]
- Wiring inside and outside electrical equipment
- Wiring to mobile electrical equipment for indoor and outdoor use
Product Specifications
< Main Specifications >
| Sheath color: Black Standard acquired: DENAN Act of Japan / ULAWM2501 / c-UL Rated voltage: 600 V Operating temperature range: 0 to 75°C (PSE) 0 to 105°C (UL) Flame retardancy: VW-1 Bending radius: finished outer diameter x 4 (fixed part) (mm) finished outer diameter x 7.5 (movable part) *These are recommended values, not guaranteed values. |
| Items | Configuration |
|---|---|
| Conductor | Annealed copper wire |
| Insulator | Heat-resistant vinyl mixture |
| Twisted | Stranded wire cores in a round shape |
| Tape | 12 cores or more wound with multiple layers of tape |
| Sheath | Oil- and heat-resistant vinyl mixture (black) |
Technical Information & Design Ideas
| Cable type | Japan*1 | UL/cUL*2 | |
|---|---|---|---|
| Compatible size | 7 contacts or less | 1 contact | 2 or more contacts |
| Rated voltage | 600V | ||
| Rated temperature | 75℃ | 105℃ | |
| Test voltage | 3,000 V AC, 1 min | ||
| Flame retardancy | 60° incline | VW-1, FT1 | |
| Compatible standards | Electrical Appliances and Materials Safety Act of Japan | UL AWM STYLE 10107 CSA C22.2 No. 210 | UL AWM STYLE 2501 CSA C22.2 No. 210 |
*The Electrical Appliances and Materials Safety Act of Japan does not apply to cables with 8 or more cores.
*For sizes of 125 mm2 or larger, cUL is not applicable.
Product Properties

| Conductor | Insulation | Number of cores | Sheath outer diameter (approx. mm) | Approximate Weight (kg/km) | Electrical Characteristics | |||
|---|---|---|---|---|---|---|---|---|
| Nominal cross-sectional area | Outer diameter (approx. mm) (configuration) | Outer diameter (approx. mm) | Allowable current (A) | Conductor resistance 20℃ (Ω/km) | Insulation Resistance 20°C (MΩkm) | |||
| 0.75 mm2 <19AWG> | 1.1 <67/0.12> | 2.7 | 2 | 8.8 | 100 | 14 | 25.8 or less | 50 or more |
| 3 | 9.2 | 110 | 12 | |||||
| 4 | 9.9 | 130 | 11 | |||||
| 6 | 12.0 | 185 | 8 | |||||
| 8 | 14.0 | 250 | 7 | |||||
| 10 | 16.0 | 330 | 7 | |||||
| 12 | 15.5 | 295 | 6 | |||||
| 16 | 17.5 | 370 | 6 | |||||
| 20 | 19.0 | 450 | 5 | |||||
| 30 | 22.5 | 630 | 5 | |||||
| 1.25 mm² <17AWG> | 1.5 <112/0.12> | 3.1 | 2 | 9.6 | 120 | 19 | 15.6 or less | 50 or more |
| 3 | 10.0 | 140 | 17 | |||||
| 4 | 11.0 | 170 | 16 | |||||
| 6 | 13.0 | 245 | 12 | |||||
| 8 | 15.5 | 325 | 9 | |||||
| 10 | 18.0 | 440 | 9 | |||||
| 12 | 17.5 | 395 | 8 | |||||
| 16 | 19.5 | 495 | 8 | |||||
| 20 | 21.5 | 610 | 7 | |||||
| 30 | 25.5 | 860 | 6 | |||||
| 2 mm² <15AWG> | 1.8 <79/0.18> | 3.6 | 1 | 6.6 | 65 | 30 | 9.50 or less | 50 or more |
| 3.4 | 2 | 10.5 | 150 | 27 | 10.1 or less | |||
| 3 | 11.0 | 180 | 23 | |||||
| 4 | 12.0 | 215 | 20 | |||||
| 6 | 14.5 | 310 | 16 | |||||
| 8 | 16.5 | 415 | 13 | |||||
| 10 | 19.5 | 560 | 13 | |||||
| 12 | 18.5 | 510 | 12 | |||||
| 16 | 21.0 | 660 | 11 | |||||
| 20 | 23.5 | 800 | 9 | |||||
| 30 | 27.5 | 1150 | 8 | |||||
| Conductor | Insulation | Number of cores | Sheath outer diameter (approx. mm) | Approximate Weight (kg/km) | Electrical Characteristics | |||
|---|---|---|---|---|---|---|---|---|
| Nominal cross-sectional area | Outer diameter (approx. mm) (configuration) | Outer diameter (approx. mm) | Allowable current (A) | Conductor resistance 20℃ (Ω/km) | Insulation Resistance 20°C (MΩkm) | |||
| 3.5 mm² <12AWG> | 2.5 [68/0.26] | 4.3 | 1 | 7.5 | 90 | 45 | 5.09 or less | 40 or more |
| 4.1 | 2 | 12.0 | 210 | 39 | 5.24 or less | |||
| 3 | 12.5 | 260 | 34 | |||||
| 4 | 14.0 | 320 | 30 | |||||
| 8 | 19.5 | 620 | 20 | |||||
| 5.5 mm2 <10AWG> | 3.1 [105/0.26] | 5.1 | 1 | 8.3 | 115 | 60 | 3.27 or less | 40 or more |
| 2 | 14.5 | 305 | 50 | 3.37 or less | ||||
| 3 | 15.0 | 375 | 44 | |||||
| 4 | 16.5 | 465 | 39 | |||||
| 8 mm2 <9AWG> | 3.7 [154/0.26] | 6.3 | 1 | 9.7 | 165 | 75 | 2.32 or less | 40 or more |
| 6.1 | 2 | 16.5 | 420 | 62 | 2.39 or less | |||
| 3 | 17.5 | 530 | 53 | |||||
| 4 | 19.5 | 660 | 47 | |||||
| 14 mm2 <6AWG> | 4,9 <88/0.45> | 7.9 | 1 | 11.5 | 245 | 107 | 1.32 or less | 40 or more |
| 2 | 20.5 | 670 | 86 | 1.36 or less | ||||
| 3 | 22.0 | 840 | 75 | |||||
| 4 | 24.0 | 1050 | 67 | |||||
| 22 mm2 <4AWG> | 7.0 <7/20/0.45> | 10.2 | 1 | 14.5 | 380 | 140 | 0.844 or less | 30 or more |
| 2 | 26.0 | 1070 | 116 | 0.869 or less | ||||
| 3 | 27.5 | 1330 | 101 | |||||
| 4 | 30.5 | 1670 | 90 | |||||
Current Reduction Factor Table
| Ambient temperature (°C) | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 |
|---|---|---|---|---|---|---|---|---|---|
| Current Reduction Factor | 1.00 | 0.94 | 0.88 | 0.82 | 0.75 | 0.67 | 0.58 | 0.47 | 0.33 |
Wire Core Identification
Arrangement diagram

Structure

A: Conductor B: Tape C: Insulator D: Sheath
Wire Core Identification
| Number of wire cores | Wire Core Identification Method |
|---|---|
| 12 contacts or less | Insulator coloring method (in the order of black, white, red, green, yellow, brown, blue, gray, orange, purple, pink, light green) |
| 13 or more cores | Numbering method (1, 2, 3, 4: are displayed continuously on the surface of the black insulator surface) |
How to Use / Usage Examples (Including Applications and Unit Examples)
- Wiring inside and outside electrical equipment.
- Wiring to mobile electrical equipment, indoors and outdoors.