Solid State Contactors US-H Series

Brand :
MITSUBISHI
Caution
Product Description
Mitsubishi electromagnetic switch.
[Features]
· Uses power semiconductor element to enable long life when using as a high frequency switch.
[Applications]
· Optimal as a non-contact AC semiconductor contactor.
Solid State Contactor US-H Series Features
- Optimal for injection molding machines, semiconductor production equipment, and other uses with high-frequency heater switching.
- The load current switching operation is performed by a semiconductor switching element, and as there are no mechanical parts, a long life with highly frequent switching can be achieved.
- No mechanical moving parts or abrading parts, and therefore no abrasion dust or contact consumption dust, resulting in clean, noiseless, comfortable use.
- Can be used at 24 to 480 V AC, a wide voltage range for the main circuit.
- Operation indicator lamp on the front surface allows users to see the operating voltage input status at a glance.
- Can select control method suited for the applied load, such as a main circuit batch control product suited for three-phase heater control (US-H□ type), or a main circuit individual control product suited for single-phase heater control (US-H□DD type).
Solid State Contactor US-H Series Specifications
| Type Name | Standard | US-H20 | US-H30 | US-H40 | US-H50 | US-H20DD | US-H30DD | US-H40DD | US-H50DD | |
|---|---|---|---|---|---|---|---|---|---|---|
| IEC 35 mm Rail Mounting | US-H20RM | US-H30RM | - | - | US-H20DDRM | US-H30DDRM | - | - | ||
| Width Dimension Decreased | US-H20UF | US-H30UF | - | - | US-H20DDUF | US-H30DDUF | - | - | ||
| Rating | Rated Operating Current (-10 To 40°C) | JEM (AC-1 Class) | 20 A | 30 A | 40 A | 50 A | 20 A | 30 A | 40 A | 50 A |
| IEC (AC-51 Class) | 20 A | 30 A | 40 A | 50 A | 20 A | 30 A | 40 A | 50 A | ||
| Applied Heater Capacity (-10 To 40°C) | 1 ø 200 V | 4 kW | 6 kW | 8 kW | 10 kW | 4 kW | 6 kW | 8 kW | 10 kW | |
| 3 Ø 200 V | 6.9 kW | 10.3 kW | 13.8 kW | 17.3 kW | - | - | - | - | ||
| 1 ø 400 V | 8 kW | 12 kW | 16 kW | 20 kW | 8 kW | 12 kW | 16 kW | 20 kW | ||
| 3 Ø 400 V | 13.8 kW | 20.7 kW | 27.7 kW | 34.6 kW | - | - | - | - | ||
| Minimum Load Current | 0.3 A | |||||||||
| Main Circuit Specifications | Main Circuit Control Method | Batch control | Individual control | |||||||
| Rated Operating Voltage | 24 to 480 V AC 50/60 Hz | |||||||||
| Operating Voltage Range | 20 to 528 V AC | |||||||||
| Rated Insulation Voltage | 500 V AC | |||||||||
| Voltage Drop Upon Closing | 1.8 V (when energized with rated current) | |||||||||
| Leakage Current When Closing | Maximum 30 mA (480 V AC 60 Hz) | |||||||||
| Surge On Current (60 Hz, Half-Wave 1 Cycle Wave Height Value) | 330 A | 800 A | 1000 A | 1,300 A | 330 A | 800 A | 1000 A | 1,300 A | ||
| Tolerance I2t(A2s) | 450 | 2,600 | 4,100 | 7,000 | 450 | 2,600 | 4,100 | 7,000 | ||
| Trigger Method | Zero voltage trigger method | |||||||||
| Closing And Breaking Current Capacity | 28 A | 42 A | 56 A | 70 A | 28 A | 42 A | 56 A | 70 A | ||
| Operation Circuit Specifications | Rated Operating Voltage | 12 to 24 V DC (Voltage ripple rate 10% or less) | ||||||||
| Operating Voltage Fluctuation Range | 85 to 110% of rated operating voltage | |||||||||
| Operation Circuit Maximum Applied Voltage | 26.4 V DC | |||||||||
| Operation Circuit Input Voltage | 10 mA or less (12 to 24 V DC) | |||||||||
| Input Impedance | 1.2 to 2.4 kΩ | |||||||||
| Operating Voltage | 9 V DC or less | |||||||||
| Open Circuit Voltage | 3 V DC or more | |||||||||
| Response Time | Maximum (1 ms+1/2 cycle) | |||||||||
| Operating Display | LED indicator lamp (Lights when applying operating voltage) | |||||||||
| Common Specifications | Withstand Voltage | 2.5 kV | ||||||||
| Insulation Resistance | 100 MΩ | |||||||||
| Rated Impulse Withstand Voltage | 6 kV | |||||||||
| Ambient Operating Temperature | -10 To 60°C (At 40°C Or Higher, Use Reduced Current) | |||||||||
| Relative Temperature | 45% to 85% RH | |||||||||
| Altitude | 2,000 m or less | |||||||||
| Vibration Resistance | 10 to 55 Hz 19.6 m/s2 | |||||||||
| Shock Resistance | 98 m/s2 | |||||||||
- Note: We also have the US-H□HZ type, which has no cooling fins.
- Note: The US-H□ type is a solid state conductor for heater load. Please do not use this for motor load.