VCTF-43Z

Caution
Product Description
Suitable for cableveyor/robot wiring
[Features]
・Compliant with the Electrical Appliance and Material Safety Law (0.75 mm2 or larger) and UL/cULAWM standards.
・Heat resistant (105°C), oil resistant and bending-resistant for flexibility.
・Features flexible 0.08mm wire strand (containing a reinforcement cord at its center).
· Sheath matte finish
Product Feature Details
Features
- Electrical Appliances and Materials Safety Act of Japan (0.75 mm2 or more) & UL/cUL AWM standard cable
- Heat resistant (105°C), oil resistant, and flex-resistant for movable applications
- 0.08 mm strand diameter flexible stranded wire (with central reinforcing yarn)
- Sheath matte
Structural Overview
| Items | Configuration |
|---|---|
| Conductor | Soft copper composite stranded wire (with central reinforcing yarn) |
| Insulator | Heat-resistant vinyl mixture |
| Twisted | Stranded wire cores in a round shape |
| Tape | Wound with multiple layers of tape |
| Shield | - |
| Sheath | Oil- and heat-resistant vinyl mixture (black) |
Technical Information & Design Ideas
| Cable type | Japan | UL/cUL |
|---|---|---|
| Compatible size | 0.75–2 mm2* | All sizes |
| Compatible size | 0.75–2 mm2* | All sizes |
| Rated voltage | 300V | |
| Rated temperature | 75℃ | 105℃ |
| Test voltage | 2,000 V AC, 1 min | |
| Flame retardancy | 60° incline | VW-1, FT1 |
| Compatible standards | Electrical Appliances and Materials Safety Act of Japan | UL AWM STYLE 2517 CSA C22.2 No.210 |
*Electrical Appliances and Materials Safety Act of Japan is not applied to 0.5 mm2, so please use it for low current circuits such as signal and communication circuits.
Specifications Table
| Conductor | Insulation | Number of cores | Unshielded | Electrical Characteristics | ||||
|---|---|---|---|---|---|---|---|---|
| Nominal cross-sectional area | Outer diameter (approx. mm) [Configuration] | Outer diameter (approx. mm) | Sheath outer diameter (approx. mm) | Approximate Weight (kg/km) | Allowable current (A) | Conductor resistance 20℃ (Ω/km) | Insulation Resistance 20°C (MΩkm) | |
| 0.5 mm2 <20 AWG> | 1.1 [6/18/0.08] | 2.35 | 2 | 7.2 | 55 | 6 | 37.8 or less | 5 or more |
| 3 | 7.3 | 65 | 6 | |||||
| 4 | 8.2 | 80 | 6 | |||||
| * | 9.0 | 95 | 5 | |||||
| 6 | 9.5 | 110 | 5 | |||||
| * | 10.5 | 125 | 5 | |||||
| 8 | 11.5 | 150 | 4 | |||||
| 10 | 12.0 | 165 | 4 | |||||
| * | 12.0 | 190 | 4 | |||||
| * | 13.0 | 205 | 4 | |||||
| * | 14.0 | 245 | 3 | |||||
| * | 16.0 | 320 | 3 | |||||
| * | 17.5 | 370 | 3 | |||||
| * | 18.5 | 425 | 3 | |||||
| 0.75 mm2 [18 AWG] | 1.5 [6/28/0.08] | 2.7 | 2 | 7.8 | 70 | 8 | 25.1 or less | 5 or more |
| 3 | 8.1 | 85 | 8 | |||||
| 4 | 9.0 | 100 | 8 | |||||
| * | 10.0 | 120 | 7 | |||||
| 6 | 10.5 | 145 | 7 | |||||
| * | 11.5 | 165 | 6 | |||||
| 8 | 12.0 | 185 | 6 | |||||
| 10 | 13.0 | 215 | 6 | |||||
| * | 14.0 | 250 | 5 | |||||
| * | 14.5 | 285 | 5 | |||||
| * | 16.0 | 345 | 5 | |||||
| * | 17.5 | 420 | 4 | |||||
| * | 19.5 | 500 | 4 | |||||
| * | 21.0 | 575 | 4 | |||||
| 1.25 mm² [16 AWG] | 1.9 [6/47/0.08] | 3.1 | 2 | 8.5 | 90 | 14 | 15.1 or less | 5 or more |
| 3 | 9.0 | 110 | 14 | |||||
| 4 | 9.8 | 135 | 14 | |||||
| * | 11.0 | 165 | 11 | |||||
| 6 | 12.0 | 195 | 10 | |||||
| * | 13.0 | 225 | 9 | |||||
| 8 | 14.0 | 255 | 9 | |||||
| 10 | 15.0 | 305 | 8 | |||||
| * | 16.5 | 380 | 8 | |||||
| * | 17.0 | 425 | 7 | |||||
| * | 18.0 | 475 | 7 | |||||
| * | 20.0 | 585 | 6 | |||||
| * | 23.5 | 775 | 6 | |||||
| * | 25.0 | 900 | 5 | |||||
| 2 mm² [14 AWG] | 2.2 [6/71/0.08] | 3.4 | 2 | 9.1 | 110 | 20 | 9.79 or less | 5 or more |
| 3 | 9.6 | 140 | 20 | |||||
| 4 | 10.5 | 175 | 20 | |||||
| * | 12.0 | 210 | 14 | |||||
| 6 | 12.5 | 250 | 13 | |||||
| * | 14.0 | 295 | 12 | |||||
| 8 | 15.0 | 335 | 11 | |||||
| 10 | 17.0 | 420 | 11 | |||||
| * | 17.5 | 480 | 10 | |||||
| * | 18.5 | 550 | 9 | |||||
| * | 19.5 | 620 | 9 | |||||
| * | 23.5 | 845 | 8 | |||||
| * | 25.5 | 1000 | 7 | |||||
| * | 27.0 | 1170 | 7 | |||||
*Product not handled by MISUMI
Product Properties

VCTF-43Z
VCTF-43ZSB
Operating temperature range
Fixing: -20 to 105°C *
During operation: 0 to 105°C
*When using below 0°C, please ensure that no external forces such as impact, bending, or vibration are applied.
Bending radius
Fixing: Recommended to be at least 4 times the cable outer diameter
During operation: Recommended to be at least 7.5 times the cable outer diameter
About allowable current
The allowable current value is the calculated value when the ambient temperature is 30°C and a single cable is laid in the air. It is not a guaranteed value.
If the ambient temperature is 30℃ or higher, multiply the allowable current value by the current reduction factor in the table below.
The allowable current value is a value calculated according to JCS0168 and is not a guaranteed value.
JCS0168: The Japanese Electric Wire & Cable Makers' Association standard "Calculation of allowable current for power cable of 33 kV or less"
Current Reduction Factor
| Ambient temperature (℃) | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 |
|---|---|---|---|---|---|---|---|---|---|
| Current Reduction Factor | 1.00 | 0.94 | 0.88 | 0.82 | 0.75 | 0.67 | 0.58 | 0.47 | 0.33 |
Wire Core Identification
| Number of wire cores | Wire Core Identification Method | |
|---|---|---|
| 2-core | Insulator coloring method | Black, white |
| 3-core | Black, white, red | |
| 4-core | Black, white, red, green/yellow | |
| 5 or more | Numbering method | Continuous display of 1, 2, 3, 4 and more on the surface of the white insulator |
Green/yellow: Green and yellow stripes (Color distribution Green 60: Yellow 40)
Arrangement diagram

Structure

A: Conductor B: Reinforcement yarn C: Insulator D: Tape E: Sheath
Instructions / Usage Examples

Applications
- Wiring for cable carriers and robots
- Wiring in oil environments