Cable for Cable Tray and Raceway Wiring and for Electronic Equipment Wiring, UE/2501 (N)/TC LF

Caution
Product Description
Cable for cable tray and raceway wiring, and for electronic equipment wiring.
[Features]
· Heat resistant PVC is used for the insulator.
·Uses oil resistant, heat resistant and flexible PVC material.
· Compatible with UL VW-1 and cUL FT1 flame retardant.
· Passed the UL vertical tray flame retardant test.
[Applications]
·Multi-cable for North America and EU.
·For cable tray and raceway wiring.
·600 V rated, UL 105℃, cUL shared device cable (categories: QPTZ, AVLV2, ZKHZ, AVLV8).
·CE marking compliant product declaration (TÜV certified product) (TÜV certificate No. (18 to 12 AWG) J2051249) (TÜV certificate No. (10 to 6 AWG) J2051252).
·Listing standards MTW and TC have been acquired and NFPA70 and 79 are supported.
Compliant standards
| Certification | UL AWM. cUL AWM | UL TC | UL MTW | TÜV.CE marking | Electrical Appliances and Materials Safety Act of Japan (18 to 10 AWG only) |
|---|---|---|---|---|---|
| Applicable Standards | UL 758 CSA C22.2 No. 210 | UL 1277 | UL 1063 | EN50525-2-51 | Ministerial Ordinance Specifying Technical Standards for Electrical Appliances |
| Type symbol | UL STYLE 2501 CSA AWM IIA/B | TC | MTW | Equivalent to H05VV5-F | Vinyl flexible cord |
| Rated voltage | 600V | 600V | 600V | 300/500 V | 300V |
| Rated temperature | 105°C | DRY 90°C WET 75°C | DRY 90°C WET 60°C | 70°C | 60°C |
| Conductor | UL 758 CSA C22.2 No. 210 | UL 1277 | UL 1063 | EN60228 | JIS C 3102 JIS C 3152 |
| Flame retardancy | VW-1.FT1 | Vertical-Tray Flame Test | VW-1 | EN50264-2-1 | JIS C 3005 4.26.2 b |

Specifications Table
| Number of wire cores | Conductor | Heat Resistant Vinyl Insulator | Oil-resistant, heat resistant, flexible vinyl sheath | Approximate Weight (kg/km) | Electrical Characteristics | |||||||
| size (AWG) | Configuration (pcs./mm) | Outer diameter (mm) | Thickness (mm) | Outer diameter (mm) | Thickness (mm) | Outer diameter approx. (mm) | Conductor resistance (Ω/km 20°C) | Insulation Resistance (MΩkm 20°C) | Withstand voltage (V/1 min.) | Allowable current (A) | ||
| 2C | 18 (0.823 mm²) | 35/0.18 | 1.2 | 0.85 | 2.9 | 1.7 | 9.4 | 95 | 22.8 or less | 60 or more | 2000 | 19 |
| 3C | 9.9 | 115 | 16 | |||||||||
| 4C | 10.6 | 135 | 15 | |||||||||
| 2C | 16 (1.30 mm²) | 26/0.26 | 1.5 | 0.85 | 3.2 | 1.7 | 10.1 | 115 | 14.3 or less | 60 or more | 2000 | 26 |
| 3C | 10.6 | 140 | 22 | |||||||||
| 4C | 11.4 | 170 | 19 | |||||||||
| 2C | 14 (2.08 mm²) | 41/0.26 | 1.9 | 0.85 | 3.6 | 1.7 | 10.8 | 140 | 9.01 or less | 60 or more | 2000 | 34 |
| 3C | 11.4 | 175 | 28 | |||||||||
| 4C | 12.3 | 210 | 25 | |||||||||
| 2C | 12 (3.30 mm²) | 65/0.254 | 2.4 | 0.85 | 4.1 | 1.7 | 11.8 | 180 | 5.45 or less | 50 or more | 2000 | 45 |
| 3C | 12.4 | 225 | 38 | |||||||||
| 4C | 13.5 | 275 | 34 | |||||||||
| 2C | 10 (5.26 mm²) | 104/0.254 | 3.1 | 0.85 | 4.8 | 1.7 | 13.2 | 240 | 3.44 or less | 50 or more | 2000 | 61 |
| 3C | 13.9 | 305 | 51 | |||||||||
| 4C | 15.2 | 385 | 46 | |||||||||
| 3C | 8 (8.36 mm²) | 7/24/0.254 | 4.2 | 1.7 | 7.6 | 1.7 | 20.0 | 560 | 2.41 or less | 50 or more | 2500 | 67 |
| 4C | 2.3 | 23.1 | 765 | 60 | ||||||||
| 2C | 6 (13.3 mm²) | 7/39/0.254 | 5.3 | 1.7 | 8.7 | 1.8 | 21.2 | 600 | 1.53 or less | 50 or more | 2500 | 100 |
| 4C | 2.3 | 25.8 | 1050 | 79 | ||||||||
* In addition to the above UL and CSA standard withstand voltage tests, it also complies with 2,000 V/5 minute tests requirements.
Product Properties
Allowable current
- The allowable current is the value for a single cable installed in air at an ambient temperature of 30°C.
- The allowable current is calculated based on JCS0168.
- Multiply the following correction factor according to the ambient temperature.
Current reduction factor (for ambient temperature)
| Ambient temperature (°C) | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
|---|---|---|---|---|---|---|---|---|
| Current Reduction Factor | 1.00 | 0.93 | 0.86 | 0.77 | 0.68 | 0.58 | 0.45 | 0.26 |
Wire Core Identification
Structure

* Annealed copper stranded wire for 12 AWG and above
Surface Printing
(1) For 18 to 10 AWG

(2) For 8 to 6 AWG

Identification

Numbers inside the circles indicate the white numbering on the black insulator.
Standard sales length