Electronics robot cable 300 V EXT-TypeII/2517 LF

Caution
Product Description
High-performance General Purpose Robot Cable
[Features]
· UL and CUL harmonized general purpose robot cable (Category: AVLV2, AVLV7).
· Compliant with ULVW-1, CULFT1 flame retardant.
· Uses a flexible vinyl material that is oil, heat, and flame resistant.
Specifications Table
| Number of wire cores | Conductor | Heat Resistant Vinyl Insulator | Smooth, oil resistant, heat resistant, flame retardant, flexible vinyl sheath | Approximate Weight (kg/km) | Electrical Characteristics | Allowable current (A) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| size (AWG) | Configuration (pcs./mm) | Outer diameter (mm) | Thickness (mm) | Outer diameter (mm) | Thickness (mm) | Outer diameter Approx. (mm) | Conductor resistance (Ω/km 20℃) | Insulation Resistance (MΩkm 20℃) | Withstand voltage (V/1 min.) | |||
| 2C | 20 (0.518 mm2) | 119/0.08 | 1.1 | 0.45 | 2.0 | 1.0 | 6.1 | 45 | 39.1 | 10 | 2000 | 9.6 |
| 3C | 1.0 | 6.4 | 55 | 9.8 | ||||||||
| 4C | 1.0 | 6.9 | 65 | 8.3 | ||||||||
| 6C | 1.1 | 8.3 | 90 | 6.4 | ||||||||
| 8C | 1.2 | 9.7 | 125 | 5.9 | ||||||||
| 10C | 1.2 | 11 | 155 | 5.6 | ||||||||
| 12C | 1.2 | 10.8 | 165 | 5.1 | ||||||||
| 16C | 1.3 | 12.1 | 210 | 4.6 | ||||||||
| 20C | 1.3 | 13.3 | 255 | 4.3 | ||||||||
| 30C | 1.5 | 16.8 | 405 | 3.8 | ||||||||
| 2C | 18 (0.823 mm2) | 168/0.08 | 1.31 | 0.45 | 2.21 | 1.0 | 6.5 | 55 | 24.0 | 12 | ||
| 3C | 1.0 | 6.9 | 65 | 12 | ||||||||
| 4C | 1.1 | 7.6 | 85 | 11 | ||||||||
| 6C | 1.1 | 8.9 | 115 | 8.4 | ||||||||
| 8C | 1.2 | 10.5 | 155 | 7.8 | ||||||||
| 10C | 1.3 | 12.1 | 195 | 7.4 | ||||||||
| 12C | 1.3 | 11.9 | 215 | 6.7 | ||||||||
| 16C | 1.3 | 13.1 | 270 | 6.1 | ||||||||
| 20C | 1.4 | 14.6 | 335 | 5.7 | ||||||||
| 30C | 1.6 | 18.5 | 525 | 5.1 | ||||||||
| 2C | 16 (1.30 mm2) | 266/0.08 | 1.64 | 0.45 | 2.54 | 1.1 | 7.4 | 70 | 15.5 | 16 | ||
| 3C | 1.1 | 7.8 | 90 | 16 | ||||||||
| 4C | 1.1 | 8.4 | 115 | 14 | ||||||||
| 6C | 1.2 | 10.1 | 160 | 11 | ||||||||
| 8C | 1.3 | 11.9 | 220 | 10 | ||||||||
| 10C | 1.3 | 13.5 | 265 | 9.6 | ||||||||
| 2C | 14 (2.08 mm^2) | 420/0.08 | 2.07 | 0.45 | 2.97 | 1.1 | 8.2 | 95 | 9.75 | 22 | ||
| 3C | 1.1 | 8.7 | 125 | 22 | ||||||||
| 4C | 1.2 | 9.7 | 155 | 19 | ||||||||
In addition to the above UL and CSA standard withstand voltage tests, it also complies with 2,000 V/5 minute test requirements.
| Bending radius (mm) | Finish radius × 6 or more (recommended) |
|---|
Other standards
| Certification | UL AWM | cUL AWM |
|---|---|---|
| Applicable Standards | UL 758 | CSA C22.2 No. 210 |
| Type symbol | UL AWM Style 2517 | CSA AWM II A/B |
| Rated voltage | 300V | 300V |
| Rated temperature | 105℃ | 105℃ |
| Conductor | UL 758 | CSA C22.2 No. 210 |
| Flame retardancy | VW-1 | FT1 |
Product Properties
Allowable current
The allowable current values are based on single cable installation in air at an ambient temperature of 30°C.
The allowable current is calculated based on JCS0168.
When a ground wire is included in a 4-core cable, the allowable current is calculated based on the 3 cores (number of current-carrying cores) excluding the ground wire.
Multiply the following correction factor according to the ambient temperature.
Current reduction factor (for ambient temperature)
| Ambient temperature (℃) | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
|---|---|---|---|---|---|---|---|---|
| Current Reduction Factor | 1.00 | 0.93 | 0.86 | 0.77 | 0.68 | 0.58 | 0.45 | 0.26 |
Movement characteristics
Number of test cycles: SS = 50,000,000 times or more
S = 20,000,000 times or more
A = 10,000,000 times or more
B = 5,000,000 times or more
C = 3,000,000 times or more
D = 1,000,000 times or more
| Note) 1 Bending | Flexible | U-shape Folded | 90° Bending | Twist | Note 2 Moving Bend | |
|---|---|---|---|---|---|---|
| Straight Line | Bend | |||||
| A | A | SS | A | A | A | C |
Note: 1. If the cable outer diameter is 20 mm or more, use C; if it is 30 mm or more, use D.
Note: 2. For cable outer diameters of 20 mm or less.
*The wiring inside the cable carrier can affect the cable's lifespan depending on the "distance traveled."
Oil Resistance
| Insulation oil | Lubricant | Cutting oil I | Cutting oil II | Hydraulic fluid | Grease |
|---|---|---|---|---|---|
| A | A | B | B | B | B |
*In the table, A to C represent the following characteristics.
A: No practical issues at all.
B: Only slight deterioration, with almost no practical issues.
C: Some deterioration, and may not be usable in certain cases.
Wire Core Identification
Arrangement diagram

Structure

A: Heat resistant vinyl insulator B: Tape C: Conductor (special soft copper stranded wire)
D: Smooth, oil resistant, heat resistant, flame retardant, flexible PVC sheath (dark blue)
Surface Printing

Identification Method

Example of 2C type identification

Example of 3C type identification

Example of 4C type identification
*The Y/G line has a green background with 3 recessed yellow bands (30% to 50%).
Numbering Identification for 6 Cores or More

Numbers inside the circles indicate the black numbering on the light blue insulator.