Electronic equipment robot cable 30 V EXT-TypeII/20276 LF

Caution
Product Description
UL and cUL high performance general purpose robot cable
[Features]
▪ UL, cUL general purpose robot cable (Category: AVLV2, AVLV7).
▪ ULVW-1 and cULFT1 flame retardance compliant.
· Uses a flexible vinyl material that is oil, heat, and flame-resistant
Flexibility
| Test Results | 50 million times | 390,000 times or more (AWG24) | 3,700,000 times or more (AWG24) |
![]() | | ![]() | |
| Test Type | U-shaped bending test | +/- 90° bending test | +/- 180° twisting test |
| Test Conditions | · Travel distance: 500 mm (round trip 1,000 mm) · Sliding speed: 88 m/min · Bending radius: 28.50 mm · Sample length: 1,300 mm | · Bending radius: 25 mm · Test speed: 44 mm/min · Test load: 3 kg · Sample length: 1,000 m | · Twisting angle: +/- 180° · Test speed: 60 times/minute · Sample length: 400 mm |
Compliant standards
| Certification | UL AWM | cUL AWM |
|---|---|---|
| Applicable Standards | UL 758 | CSA C22.2 No. 210 |
| Type symbol | UL STYLE 20276 | CSA AWM II A/B |
| Rated voltage | 30V | 30V |
| Rated temperature | 80℃ | 80℃ |
| Conductor | UL 758 | CSA C22.2 No. 210 |
| Flame retardancy | VW-1 | FT1 |
Specifications Table
| Number of wire cores Number of pairs | Conductor | Heat Resistant Vinyl Insulator | Smooth, oil resistant, heat resistant, flame retardant, flexible vinyl sheath | Approximate Weight (kg/km) | Electrical Characteristics | Allowable current (A) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| size (AWG) | Configuration (pcs./mm) | Outer diameter (mm) | Thickness (mm) | Outer diameter (mm) | Thickness (mm) | Outer diameter Approx. (mm) | Conductor resistance (Ω/km 20℃) | Insulation Resistance (MΩkm 20℃) | Withstand voltage (V/1 min.) | |||
| 1P | 28 (0.0804 mm2) | 19/0.08 | 0.4 | 0.23 | 0.86 | 0.65 | 3.1 | 11 | 235 or less | 10 or more | 500 | 2.5 |
| 3C | 0.65 | 3.2 | 15 | 230 or less | 2.1 | |||||||
| 2P | 0.65 | 4.0 | 19 | 235 or less | 2.0 | |||||||
| 3P | 0.65 | 4.5 | 23 | 1.7 | ||||||||
| 4P | 0.65 | 4.8 | 27 | 1.5 | ||||||||
| 5P | 0.65 | 5.2 | 32 | 1.4 | ||||||||
| 1P | 26 (0.15 mm2) | 30/0.08 | 0.51 | 0.23 | 0.97 | 0.9 | 3.8 | 18 | 143 | 10 | 500 | 2.0 |
| 3C | 0.9 | 4.0 | 21 | 136 | 2.0 | |||||||
| 2P | 1.0 | 4.9 | 28 | 143 | 2.0 | |||||||
| 3P | 1.0 | 5.7 | 36 | 1.9 | ||||||||
| 4P | 1.0 | 6.1 | 41 | 1.7 | ||||||||
| 5P | 1.0 | 6.6 | 48 | 1.6 | ||||||||
| 6P | 1.0 | 7.1 | 55 | 1.5 | ||||||||
| 7P | 1.1 | 7.6 | 65 | 1.4 | ||||||||
| 8P | 1.1 | 8.3 | 75 | 1.4 | ||||||||
| 10P | 1.1 | 8.4 | 85 | 1.3 | ||||||||
| 12P | 1.1 | 9.2 | 95 | 1.2 | ||||||||
| 15P | 1.1 | 10.1 | 115 | 1.1 | ||||||||
| 20P | 1.2 | 11.3 | 150 | 1.0 | ||||||||
| 25P | 1.2 | 12.8 | 180 | 0.9 | ||||||||
| 2C | 24 (0.25 mm2) | 48/0.08 | 0.75 | 0.23 | 1.21 | 0.9 | 4.3 | 25 | 97.9 | 10 | 500 | 3.0 |
| 3C | 0.9 | 4.5 | 28 | 3.0 | ||||||||
| 4C | 0.9 | 4.8 | 33 | 2.0 | ||||||||
| 5C | 0.9 | 5.2 | 37 | 2.0 | ||||||||
| 6C | 0.9 | 5.6 | 43 | 2.0 | ||||||||
| 8C | 1.0 | 6.5 | 60 | 2.0 | ||||||||
| 10C | 1.0 | 7.4 | 65 | 2.0 | ||||||||
| 12C | 1.0 | 7.3 | 70 | 2.0 | ||||||||
| 16C | 1.0 | 8.0 | 90 | 1.8 | ||||||||
| 20C | 1.1 | 8.9 | 110 | 1.6 | ||||||||
| 30C | 1.1 | 10.6 | 155 | 1.4 | ||||||||
| 40C | 1.2 | 12.0 | 205 | 1.3 | ||||||||
| 2C | 22 (0.35 mm2) | 72/0.08 | 0.90 | 0.23 | 1.36 | 0.9 | 4.6 | 29 | 62.2 | 10 | 500 | 4.0 |
| 3C | 0.9 | 4.8 | 34 | 4.0 | ||||||||
| 4C | 0.9 | 5.2 | 39 | 3.0 | ||||||||
| 5C | 1.0 | 5.8 | 45 | 3.0 | ||||||||
| 6C | 1.0 | 6.2 | 55 | 3.0 | ||||||||
| 8C | 1.0 | 7.1 | 75 | 3.0 | ||||||||
| 10C | 1.0 | 8.0 | 85 | 2.0 | ||||||||
| 12C | 1.0 | 7.9 | 90 | 2.0 | ||||||||
| 16C | 1.1 | 8.9 | 120 | 2.0 | ||||||||
| 20C | 1.1 | 9.7 | 140 | 2.0 | ||||||||
| 30C | 1.2 | 11.8 | 210 | 1.8 | ||||||||
| 40C | 1.2 | 13.2 | 270 | 1.7 | ||||||||
| 2C | 20 (0.59 mm2) | 119/0.08 | 1.1 | 0.25 | 1.60 | 0.9 | 5.1 | 38 | 39.1 | 10 | 500 | 6.0 |
| 3C | 0.9 | 5.3 | 44 | 5.0 | ||||||||
| 4C | 1.0 | 6.0 | 55 | 4.0 | ||||||||
| 5C | 1.0 | 6.4 | 65 | 4.0 | ||||||||
| 6C | 1.0 | 6.9 | 75 | 4.0 | ||||||||
| 8C | 1.0 | 7.9 | 100 | 4.0 | ||||||||
| 10C | 1.1 | 9.3 | 125 | 3.0 | ||||||||
| 12C | 1.1 | 9.1 | 130 | 3.0 | ||||||||
| 16C | 1.1 | 10.0 | 165 | 3.0 | ||||||||
| 20C | 1.2 | 11.2 | 210 | 2.0 | ||||||||
| 24C | 1.2 | 12.3 | 250 | 2.0 | ||||||||
| 30C | 1.2 | 13.5 | 300 | 2.0 | ||||||||
| 40C | 1.3 | 15.2 | 395 | 2.0 | ||||||||
Product Properties
The allowable current values are based on single cable installation in air at an ambient temperature of 30°C.
Multiply the following correction factor according to the ambient temperature and installation conditions.
Current reduction factor (for ambient temperature)
| Ambient temperature (℃) | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
|---|---|---|---|---|---|---|---|---|
| Current Reduction Factor | 1.00 | 0.89 | 0.77 | 0.63 | 0.45 | - | - | - |
Current reduction factor (for multiple cable installations)
| Number of cable | 2 to 3 | 4 | 5 to 6 | 7 to 15 | 16 to 40 | 41 to 46 | 61 or more |
|---|---|---|---|---|---|---|---|
| Current Reduction Factor | 0.70 | 0.63 | 0.56 | 0.49 | 0.43 | 0.39 | 0.34 |
Movement characteristics
Number of test cycles: SS = 50,000,000 times or more
S = 20,000,000 times or more
A = 10,000,000 times or more
B = 5,000,000 times or more
C = 3,000,000 times or more
D = 1,000,000 times or more
| Note) 1 Bending | Flexible | U-shape Folded | 90° Bending | Twist | Note 2 Moving Bend | |
|---|---|---|---|---|---|---|
| Straight Line | Bend | |||||
| A | A | A | A | A | A | C |
Note: 1. If the cable outer diameter is 20 mm or more, use C; if it is 30 mm or more, use D.
Note: 2. For cable outer diameters of 20 mm or less.
*Wiring inside a cable carrier may affect the cable's service life depending on the "travel distance." If you plan to use it with a travel distance of 5 m or more, please consult us.
Oil Resistance
| Insulation oil | Lubricant | Cutting oil I | Cutting oil II | Hydraulic fluid | Grease |
|---|---|---|---|---|---|
| A | A | B | B | B | B |
*In the table, A to C represent the following characteristics.
A: No practical issues at all.
B: Only slight deterioration, with almost no practical issues.
C: Some deterioration, and may not be usable in certain cases.
Wire Core Identification
Multi-core Type Arrangement Diagram

Multi-core Type Structure Diagram

A: Heat resistant PVC insulator B: Tape C: Conductor (special soft copper stranded wire)
D: Oil resistant, heat resistant, flame retardant, flexible PVC sheath (dark blue)
Multi-pair Type Arrangement Diagram

Multi-pair Type Structure Diagram

A: Heat resistant PVC insulator B: Tape C: Conductor (special soft copper stranded wire)
D: Oil resistant, heat resistant, flame retardant, flexible PVC sheath (dark blue)
Surface Printing

Identification of Multi-core Cables

The numbers inside the circles indicate the conductor numbers in the multi-core type identification table.
Multi-core Type Identification Table

*Short dots: 1 mm, long dots: 2 mm, spacing: 1 mm, pitch: approx. 12 mm
Identification of Multi-pair Cables

The numbers inside the circles indicate the pair numbers in the multi-pair type identification table.
*1P is sky blue × pink
Multi-pair Type Identification Table

*Short dots: 1 mm, long dots: 2 mm, spacing: 1 mm, pitch: approx. 12 mm
Pair examples

The color of the insulator shall be the same for both the first and second wires.
The color of the pixel marks on the first and second wires shall be black and red, respectively.