Electronics robot cable 600 V EXT-TypeII/2501 LF

Caution
Product Description
600V compatible high-performance general purpose robot cable
[Features]
▪ UL, cUL shared, general purpose robot cable (Category: AVLV2, AVLV7).
▪ Compliant with ULVW-1, cULFT1 flame retardant.
· Use of a flexible vinyl material that is oil, heat, and flame resistant
Product Feature Details
- UL and cUL shared robot cable
- Compatible with ULVW-1 and cULFT1 flame retardant
- Uses smooth, oil resistant, heat resistant, flame retardant, flexible vinyl material
Specifications Table
| Number of wire cores | Conductor | Heat Resistant Vinyl Insulator | Smooth, oil resistant, heat resistant, flame retardant, flexible vinyl sheath | Approximate Weight (kg/km) | Electrical Characteristics | Allowable current (A) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| size (AWG) | Configuration (pcs./mm) | Outer diameter (mm) | Thickness (mm) | Outer diameter (mm) | Thickness (mm) | Outer diameter Approx. (mm) | Conductor resistance (Ω/km 20℃) | Insulation Resistance (MΩkm 20℃) | Withstand voltage (V/1 min.) | |||
| 2C | 18 (0.823 mm2) | 168/0.08 | 1.31 | 0.85 | 3 | 1.7 | 9.6 | 100 | 24 | 50 | 2000 | 13 |
| 3C | 10.1 | 120 | 13 | |||||||||
| 4C | 10.9 | 140 | 11 | |||||||||
| 6C+1C | 13.9 | 240 | 9.5 | |||||||||
| 8C+1C | 15.7 | 295 | 8.7 | |||||||||
| 10C+1C | 16.5 | 330 | 8 | |||||||||
| 12C+1C | 17.3 | 365 | 7.5 | |||||||||
| 20C+1C | 20.8 | 555 | 6.3 | |||||||||
| 30C+1C | 2.3 | 25.3 | 810 | 5.5 | ||||||||
| 2C | 16 (1.30 mm2) | 266/0.08 | 1.64 | 0.85 | 3.3 | 1.7 | 10.3 | 120 | 15.5 | 50 | 2000 | 17 |
| 3C | 10.8 | 145 | 17 | |||||||||
| 4C | 11.7 | 175 | 15 | |||||||||
| 6C+1C | 14.8 | 285 | 12 | |||||||||
| 10C+1C | 17.7 | 400 | 10 | |||||||||
| 12C+1C | 18.6 | 460 | 9.6 | |||||||||
| 20C+1C | 2.3 | 23.7 | 740 | 8.1 | ||||||||
| 30C+1C | 27.4 | 1030 | 7 | |||||||||
| 40C+1C | 30.4 | 1300 | 6.3 | |||||||||
| 2C | 14 (2.08 mm^2) | 420/0.08 | 2.07 | 0.85 | 3.8 | 1.7 | 11.1 | 145 | 9.75 | 50 | 2000 | 23 |
| 3C | 11.7 | 180 | 23 | |||||||||
| 4C | 12.7 | 220 | 20 | |||||||||
| 7C | 16.1 | 360 | 16 | |||||||||
| 11C | 19.3 | 510 | 13 | |||||||||
| 13C | 20.2 | 585 | 12 | |||||||||
| 21C | 2.3 | 26 | 970 | 10 | ||||||||
Other standards
| Certification | UL AWM | cUL AWM |
|---|---|---|
| Applicable Standards | UL 758 | CSA C22.2 No. 210 |
| Type symbol | UL STYLE 2501 | CSA AWM II A/B |
| Rated voltage | 600V | 600V |
| Rated temperature | 105℃ | 105℃ |
| Conductor | UL 758 | CSA C22.2 No. 210 |
| Flame retardancy | VW-1 | FT1 |
Product Properties
Ground wire structure
| Conductor | Heat Resistant Vinyl Insulator | |||
|---|---|---|---|---|
| size (AWG) | Configuration (pcs./mm) | Outer diameter (mm) | Thickness (mm) | Outer diameter (mm) |
| 14 | 420/0.08 | 2.07 | 0.85 | 3.8 |
*When the number of wire cores is indicated as "+1C", it means a 14AWG [Y/G] ground wire is included.
(Example) 6C+1C×18AWG: 6×18AWG + 1×14AWG (ground). For 3-core, 4-core, and 14AWG cables, one Y/G ground wire of the same size is included.
*In addition to the above UL and CSA standard withstand voltage tests, it also complies with 2,000 V/5 minute test requirements.
Allowable current
The allowable current values are based on single cable installation in air at an ambient temperature of 30°C.
The allowable current is calculated based on JCS0168.
If a ground wire is included in a 4-core cable, the allowable current is calculated using the remaining 3 cores (number of current-carrying cores), excluding the ground wire.
Multiply the following correction factor according to the ambient temperature and installation conditions.
Current reduction factor (for ambient temperature)
| Ambient temperature (℃) | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
|---|---|---|---|---|---|---|---|---|
| Current Reduction Factor | 1.00 | 0.93 | 0.86 | 0.77 | 0.68 | 0.58 | 0.45 | 0.26 |
Movement characteristics
Number of test cycles: SS = 50,000,000 times or more
S = 20,000,000 times or more
A = 10,000,000 times or more
B = 5,000,000 times or more
C = 3,000,000 times or more
D = 1,000,000 times or more
| Note) 1 Bending | Flexible | U-shape Folded | 90° Bending | Twist | Note 2 Moving Bend | |
|---|---|---|---|---|---|---|
| Straight Line | Bend | |||||
| A | A | SS | A | A | A | C |
Note: 1. If the cable outer diameter is 20 mm or more, use C; if it is 30 mm or more, use D.
Note: 2. For cable outer diameters of 20 mm or less.
*Wiring inside a cable carrier may affect the cable's service life depending on the "travel distance." If you plan to use it with a travel distance of 5 m or more, please consult us.
Oil Resistance
| Insulation oil | Lubricant | Cutting oil I | Cutting oil II | Hydraulic fluid | Grease |
|---|---|---|---|---|---|
| A | A | B | B | B | B |
*In the table, A to C represent the following characteristics.
A: No practical issues at all.
B: Only slight deterioration, with almost no practical issues.
C: Some deterioration, and may not be usable in certain cases.
Wire Core Identification
Arrangement diagram

Structure

A: Heat resistant vinyl insulator B: Tape C: Conductor (special soft copper stranded wire)
D: Smooth, oil resistant, heat resistant, flame retardant, flexible PVC sheath (dark blue)
Surface Printing

Identification of Multi-core Cables

Numbers inside the circles indicate the white numbering on the black insulator.
*The Y/G line has a green background with 3 recessed yellow bands (30% to 50%).