ø16 XA Series, Emergency Stop Switch

Caution
Product Description
ø16 XA Series Emergency Stop Switch.
[Features]
・ 4 contacts of ø16, short body 27.9 mm push-button switch for emergency stop
・ Safe break action with maximum safety
・ Panel depth dimension is 27.9 mm for all 1 to 4 contacts
・ Illuminated type achieves the same depth dimension as non-illuminated type
・ Available with 1 to 4 main contacts (b contact) and 1 monitor contact (a contact)
・ It supports 2 types of reset operations (Push Lock Pull or Turn Reset)
・ Direct circuit operation function (Compliant with IEC60947-5-5: section 5.2, IEC60947-5-1 Annex K)
・ Safety lock mechanism (IEC60947-5-5: section 6.2)
・ Protection structure IP65 (IEC60529)
・ Contacts are gold plated contacts
・ Two button sizes are available: ø29 (medium size) and ø40 (large size)
・ Non-illuminated button colors are available in 2 types for "emergency stop" red and "stop" gray (Gray only has medium-sized buttons)
・ Dark red (R): Munsell code 5R4/12 (Approximation)
・ Bright red (RH): Munsell code 7.5R4.5/14 (Approximation)
・ UL, c-UL certified product and EN standard compliant product
・ UL emergency stop category certified product
Product Information of IDEC Emergency Stop Switches / Safety Switches
- IDEC Emergency Stop Switches / Safety Switches for space saving and safety
- Space-saving design:Approximately 30% shorter in depth than conventional products, making it more compact
- Safety design:The main contact will be turned off even if the switch is damaged by impact (patented by the manufacturer)
Space Saving of IDEC Emergency Stop Switches / Safety Switches
Emergency Stop Switches / Safety Switches, The depth has been shortened by approximately 30% compared to conventional products, resulting in space saving.

Safety of IDEC Emergency Stop Switches / Safety Switches
- Safe Potential Structure
- IDEC Emergency Stop Switches / Safety Switches unique safety structure keeps the main contacts OFF even if the switch is damaged by excessive force or impact (IDEC patented)

Safety Standards of IDEC Emergency Stop Switches / Safety Switches

Direct opening function
Even if the contacts are welded, pressing the button directly separates the contacts, reliably breaking the circuit
(Complies with IEC60947-5-5: 5.2, IEC60947-5-1 Annex K).

Safety lock mechanism
To prevent unexpected sudden start-up, the contacts open at the same time as the actuator latches
(IEC60947-5-5: Section 6.2) .

Compliant with various safety standards
UL, c-UL certified products and EN standard compliant products, UL emergency stop category certified products
UL508, CSA C22.2 No.14, IEC60947-5-5, UL991, NFPA79, EN60947-5-1, EN60947-5-5, GB14048.5