Micro relay G5V-1

Caution
Product Description
[Features]
· A small and high sensitivity single-pole relay for signal switching.
· Small size: 12.5 (L) × 7.5 (W) × 10 (H) mm.
· Features a wide contact switching region of 1mA to 1 A.
· High sensitivity coil: 150mW.
· A sealed plastic type with high environmental resistance.
· FCCpart68 compliant (1,500V, 10 × 160 μs) between coil-contacts.
Micro Relay Specifications

G5V-1 external appearance

G5V-1 dimensional outline drawing

PCB processing drawing
Ratings (Operating Coil/Standard Type, Model G5V-1)
| Items | Rated Current (mA) | Coil Resistance (Ω) | Operating Voltage (V) | Release Voltage (V) | Maximum Allowable Voltage (V) | Power Consumption (mW) | |
|---|---|---|---|---|---|---|---|
| Rated Voltage (V) | |||||||
| DC | 3 | 50 | 60 | 80% or Less | 10% or More | 200% (at 23°C) | Approx. 150 |
| 5 | 30 | 167 | |||||
| 9 | 16.7 | 540 | |||||
| 12 | 12.5 | 960 | |||||
| 24 | 6.25 | 3,840 | |||||
Note 1: The rated current and coil resistance are measured at a coil temperature of +23°C and a tolerance of 10%.
Note 2: The operating characteristics are measured at a coil temperature of +23°C.
3. The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
4. Model G5V-1-2 (with an operating voltage of 70% or less) is also available as part of a special product series.
Switching Part (Contact Part)
| Load | Resistance Load |
|---|---|
| Contact Touching Mechanism | Single Crossbar Contact |
| Contact Material | Au Alloy + Ag |
| Rated Load | 125 V AC 0.5 A, 24 V DC 1 A |
| Rated Conduction Current | 2 A |
| Maximum Contact Voltage Value | 125 V AC 60 V DC |
| Maximum Contact Current Value | 1 A |
Performance
| Contact Resistance *1 | 100 mΩ or Less | |
|---|---|---|
| Turn-ON Time | 5 ms or Less | |
| Turn-OFF Time | 5 ms or Less | |
| Insulation Resistance *2 | 1,000 MΩ or More | |
| Withstand Voltage | Between Coil and Contact | 1,000 V AC 50/60 Hz 1 min |
| Between Contacts of Same Polarity | 400 V AC 50/60 Hz 1 min | |
| Vibration | Durability | 10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm) |
| Malfunction | 10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm) | |
| Shock / Impact | Durability | 1,000 m/s2 |
| Malfunction | 100 m/s2 | |
| Durability | Mechanical | 5,000,000 Times or More (Switching Frequency: 36,000 Times/h) |
| Electrical | 100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h) | |
| Failure Rate P Level (Reference Value *3) | 5 V DC, 1 mA | |
| Ambient Operating Temperature | -40 to +70°C (Standard Type), -40 to +90°C (Model G5V-1-T90) (Assuming No Freezing or Condensation) | |
| Operating Ambient Humidity | 5 to 85% RH | |
| Weight | Approx. 2 g | |
Note: The above values are the initial default values.
*1. Measurement conditions: 1 V DC 10 mA, voltage drop method.
*2. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter between coil contacts and 250 V DC between contacts of the same polarity.
*3. This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 100 Ω. These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.