Micro relay G6E

Caution
Product Description
A small, high-sensitivity 1-pole signal switching relay.
[Features]
・ Impressive power consumption is only 98 mW (rated power consumption: 200 mW), achieving high sensitivity
・ Designed to ensure an impact resistant voltage of 1,500 V (10 × 160 μs) and comply with the FCC standard
・ Adopted stick packaging in consideration of support for automatic mounting
・ Plastic seal type allows automatic soldering
・ Series of ultrasonic cleaning compatible types
・ Obtained UL and CSA standards as standard
[Applications]
・ Mounted on PCBs for communication equipment, office equipment, test and measuring instrument, disaster and crime prevention equipment, security equipment, etc.
Micro Relay G6E Specifications

G6E external appearance

Single stable type dimensional drawing
Model G6E-134P-US, Model G6E-134PL-US, Model G6E-134P-US-U
Average Dimensions
Units: mm

Single stable type PCB processing dimensions
Model G6E-134P-US, Model G6E-134PL-US, Model G6E-134P-US-U
Dimensional tolerance: ±0.1 mm
Units: mm

Dual coil latching type dimensional drawing
Model G6EK-134P-US-U
Average dimensions
Units: mm

Dual coil latching type PCB processing dimensions
Model G6EK-134P-US-U
Dimensional tolerance: ±0.1 mm
Units: mm
Standard type (UL standard, CSA standard certification)
| Classification | Single Stable Type | |||
|---|---|---|---|---|
| Structure | Standard Type | Low Sensitivity Type | ||
| Contact Structure | Model | Coil Rated Voltage (V) | Model | Coil Rated Voltage (V) |
| 1c | Model G6E-134P-US | 5 DC | Model G6E-134P-US | 5 DC |
| 12 DC | 12 DC | |||
| 24 DC | 24 DC | |||
| 48 DC | - | - | ||
Ultrasonic Cleaning Compatible Type
| Classification | Single Stable Type | Dual Coil Latching Type | ||
|---|---|---|---|---|
| Structure | Standard Type | |||
| Contact Structure | Model | Coil Rated Voltage (V) | Model | Coil Rated Voltage (V) |
| 1c | Model G6E-134P-US-U | 5 DC | Model G6EK-134P-US-U | 5 DC |
| 12 DC | 12 DC | |||
| 24 DC | 24 DC | |||
Note: Specify the rated voltage (V) of the coil when placing your order.
E.g. Model G6E-134P-US DC5
Furthermore, the notation of the voltage specification on the product case as well as on the packaging will be marked as □□ V DC.
Micro Relay G6E Performance
| Classification | Single Stable Type | Dual Coil Latching Type_x000D_ | |
|---|---|---|---|
| Contact Resistance *1 | 50 mΩ or Less _x000D_ | ||
| Set Time *2 | 5 ms or Less (Approx. 2.9 ms., or Approx. 2.4 ms for 48 V DC coil) | 5 ms or Less (Approx. 2.3 ms) | |
| Reset Time *2 | 5 ms or Less (Approx. 1.3 ms) | 5 ms or Less (Approx. 2.3 ms) _x000D_ | |
| Minimum Set Pulse Width | - | 15 ms | |
| Minimum Reset Pulse Width | - | 15 ms | |
| Insulation Resistance *3 | 1,000 MΩ or More (with 500 V DC Megohmmeter)_x000D_ | ||
| Impulse Withstand Voltage | Between Coil and Contact | 2,500 V 10 × 160 (μs) (Complies with FCC part 68) | |
| Between Contacts of Same Polarity | 1,500 V 10 × 160 (μs) (Complies with FCC part 68) | ||
| Withstand Voltage | Between Coil and Contact | 1,500 V AC 50/60 Hz 1 min | |
| Between Contacts of Same Polarity | 1,000 V AC 50/60 Hz 1 min | ||
| Vibration | Durability | 10 to 55 to 10 Hz, Semi Amplitude 2.5 mm (Double Amplitude 5 mm) | |
| Malfunction | 10 to 55 to 10 Hz, Semi Amplitude 1.65 mm (Double Amplitude 3.3 mm) | ||
| Shock / Impact | Durability | 1,000 m/s2 | |
| Malfunction | 300 m/s2 | ||
| Durability_x000D_ | Mechanical | 100,000,000 Times (Switching Frequency: 36,000 Times/h) | |
| Electrical_x000D_ | 100,000 Times or More (Rated Load 125 V AC 0.4 A Resistance Load, 125 V AC 0.2 A Inductive Load) (Switching Frequency 1,800 Times/h) | ||
| 500,000 Times or More (Rated Load 30 V DC 2 A Resistance Load, 30 V DC 1 A Inductive Load) (Switching Frequency 1,800 Times/h) | |||
| 200,000 Times or More (30 V DC 3 A Resistance Load) (Switching Frequency: 1,800 Times/h) | |||
| Failure Rate P Level (Reference Value *4) | DC 10 mV 10 μA | ||
| Ambient Operating Temperature | -40 to +70°C (Assuming No Freezing or Condensation) | ||
| Operating Ambient Humidity | 5 to 85% RH | ||
| Weight | Approx. 2.7 g | ||
Note: The above values are the initial default values.
- *1. Measurement conditions: 5 V DC 1 A, voltage drop method.
- *2. The values within ( ) are the actual values.
- *3. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter.
- *4. This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 50 Ω. These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.
*Refer to the catalog for product information other than that above.