Electrode Holder - BF-□(R)/BS-1(T)

Caution
Product Description
Electrode holding device BF-□ (R) / BS-1 (T)
[Features]
· A wide selection is available to match usage environments, such as those with high temperatures or high pressure,
· or in which chemical liquids are used.
· Type BF-1 is optimal for controlling liquids with low resistivity such as sewage.
· Type BF-(R) is used when attachment strength is required.
· Type BS-1 when high temperature and high pressure conditions are severe.
· Type BS-1T is used when corrosion resistance is required.
Catalog product information click here
Electrode Holder Specifications

Electrode Holder external appearance

BF-1 outline drawing
Weight: approx. 75 g

BF-1 dimensional outline drawing, Units: mm

BF-1 dimensional outline drawing, Units: mm

BF-1 Mounting hole machining dimensions, Units: mm

BS-1T outline drawing

BS-1T structural drawing

BS-1T dimensional outline drawing, Units: mm

BS-1T mounting hole machining dimensions
M18 P = 1.5 (fine screw thread)
| Item | Format | ||||
|---|---|---|---|---|---|
| Model BF-1 | Model BF-3(R) *1 | Model BF-5(R) *1 | Model BS-1 | Model BS-1T | |
| Number Of Poles | 1 | 3 | 5 | - | - |
| Insulation Material | PPS resin (metallic section is SUS) | Fluororesin (PFA) | |||
| Insulation Resistance | 100 MΩ | ||||
| Operating Temperature | Electrode: -10 to +150°C (no icing within specified conditions) Terminal: -10 to +70°C (no condensation or icing within specified conditions) | 250°C max. | 180°C max. | ||
| Operating Pressure | Atmospheric pressure | 1.96 MPa *2 | 981 kPa *2 | ||
| Applications | Liquids with low specific resistance such as wastewater and cloudy water | General applications for purified water, wastewater, etc. | Boiler water level detection or high temperature tanks | Acidic or alkaline solution level detection | |
- *1 Two-wire electrode holders (R types) have a built-in resistance of 6.8 kΩ. They should be used with the two-wire 61F controllers.
- *2 There must be a sufficient ambient temperature in high-pressure environments to prevent vapor leakage. Use according to the pressure-temperature curve. See the catalog for the pressure-temperature curve.
- *See the catalog for specifications other than those detailed above.