PBA Series (300W - 1,500 W)

PBA Series (300W - 1,500 W)

It is an epoch-making series that is half the volume than the conventional series. Flagship model with general-purpose unit power supply excellent in harmonic compatibility, high efficiency, small size, multi-function, variation etc.

[Features]
· Compared with our conventional volume 35%
· Output voltage can be varied to near 0 V
· Can be used as a constant current power source (requires an external circuit)
· Supports various optional parts such as dedicated harness
· Maintenance improvement of fans greatly improved
· With various alarms
· Output voltage tracking type over-voltage-protection (option)
· AUX (12V With
· Parallel operation / N+1 Parallel redundant operation
· SEMI F47 Standard correspondence possible

PDF

Part Number

Configured Part Number is shown.

 
Part Number
PBA1000F-3R3
PBA1000F-3R3-C
PBA1000F-3R3-CF1
PBA1000F-3R3-CF3
PBA1000F-3R3-CF4
PBA1000F-3R3-F1
PBA1000F-3R3-F3
PBA1000F-3R3-F4
PBA1000F-3R3-G
PBA1000F-3R3-U
PBA1000F-5
PBA1000F-5-C
PBA1000F-5-CF1
PBA1000F-5-CF3
PBA1000F-5-CF4
PBA1000F-5-F1
PBA1000F-5-F3
PBA1000F-5-F4
PBA1000F-5-G
PBA1000F-5-GU
PBA1000F-5-U
PBA1000F-7R5
PBA1000F-7R5-C
PBA1000F-7R5-CF3
PBA1000F-7R5-CF4
PBA1000F-7R5-F1
PBA1000F-7R5-F3
PBA1000F-7R5-F4
PBA1000F-7R5-G
PBA1000F-7R5-U
PBA1000F-12
PBA1000F-12-C
PBA1000F-12-CF3
PBA1000F-12-CF4
PBA1000F-12-F1
PBA1000F-12-F3
PBA1000F-12-F4
PBA1000F-12-G
PBA1000F-12-U
PBA1000F-15
PBA1000F-15-C
PBA1000F-15-CF3
PBA1000F-15-CF4
PBA1000F-15-CU
PBA1000F-15-F1
PBA1000F-15-F3
PBA1000F-15-F4
PBA1000F-15-G
PBA1000F-15-U
PBA1000F-24
PBA1000F-24-C
PBA1000F-24-CF1
PBA1000F-24-CF3
PBA1000F-24-CF4
PBA1000F-24-D18
PBA1000F-24-F1
PBA1000F-24-F3
PBA1000F-24-F4
PBA1000F-24-G
PBA1000F-24-U
Part NumberVolume DiscountDays to ShipRoHSShape Output power
(W)
Input Voltage Output voltage (Single only) Rated output current (single only)
(A)
Included Function Safety standards Height
(mm)
Width
(mm)
Depth
(mm)
Input Voltage
(V)
Maximum output power
(W)
Voltage settings reliability
(V)
Output voltage variation
(V)
Other optional functions Peak current
(A)
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC3.3V200Fan for cooling / Parallel / Alarm OutputCE / UL / CUL / TUV / CSA61150240AC85 to 264/DC120 to 3506603.3–3.42.64 to 3.96NA-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC3.3V200Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 3506603.3–3.42.64 to 3.96NA-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC3.3V200Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 3506603.3–3.42.64 to 3.96Long life fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC3.3V200Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 3506603.3–3.42.64 to 3.96Fan reverse mounting support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC3.3V200Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 3506603.3–3.42.64 to 3.96Low speed fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC3.3V200Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 3506603.3–3.42.64 to 3.96Long life fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC3.3V200Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 3506603.3–3.42.64 to 3.96Fan reverse mounting support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC3.3V200Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 3506603.3–3.42.64 to 3.96Low speed fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC3.3V200Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 3506603.3–3.42.64 to 3.96Low leak current-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC3.3V200Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 3506603.3–3.42.64 to 3.96Instantaneous input voltage dip support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC5V200Fan for cooling / Parallel / Alarm OutputCE / UL / CUL / TUV / CSA61150240AC85 to 264/DC120 to 35010005 to 5.153.96 to 6NA-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC5V200Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010005 to 5.153.96 to 6NA-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC5V200Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010005 to 5.153.96 to 6Long life fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC5V200Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010005 to 5.153.96 to 6Fan reverse mounting support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC5V200Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010005 to 5.153.96 to 6Low speed fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC5V200Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010005 to 5.153.96 to 6Long life fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC5V200Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010005 to 5.153.96 to 6Fan reverse mounting support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC5V200Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010005 to 5.153.96 to 6Low speed fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC5V200Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010005 to 5.153.96 to 6Low leak current-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC5V200Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010005 to 5.153.96 to 6 instantaneous input voltage dip support specifications / Low leak current -
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC5V200Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010005 to 5.153.96 to 6Instantaneous input voltage dip support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DC[Other] DC7.5V134Fan for cooling / Parallel / Alarm OutputCE / UL / CUL / TUV / CSA61150240AC85 to 264/DC120 to 35010057.5 to 7.85.25 to 8.25NA-
26 Day(s) or more 10[With Cover] With Cover1000AC/DC[Other] DC7.5V134Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010057.5 to 7.85.25 to 8.25NA-
26 Day(s) or more 10[With Cover] With Cover1000AC/DC[Other] DC7.5V134Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010057.5 to 7.85.25 to 8.25Fan reverse mounting support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DC[Other] DC7.5V134Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010057.5 to 7.85.25 to 8.25Low speed fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DC[Other] DC7.5V134Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010057.5 to 7.85.25 to 8.25Long life fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DC[Other] DC7.5V134Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010057.5 to 7.85.25 to 8.25Fan reverse mounting support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DC[Other] DC7.5V134Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010057.5 to 7.85.25 to 8.25Low speed fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DC[Other] DC7.5V134Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010057.5 to 7.85.25 to 8.25Low leak current-
26 Day(s) or more 10[With Cover] With Cover1000AC/DC[Other] DC7.5V134Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 35010057.5 to 7.85.25 to 8.25Instantaneous input voltage dip support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC12V88Fan for cooling / Parallel / Alarm OutputCE / UL / CUL / TUV / CSA61150240AC85 to 264/DC120 to 350105612 to 12.488.25 to 13.2NA-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC12V88Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105612 to 12.488.25 to 13.2NA-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC12V88Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105612 to 12.488.25 to 13.2Fan reverse mounting support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC12V88Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105612 to 12.488.25 to 13.2Low speed fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC12V88Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105612 to 12.488.25 to 13.2Long life fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC12V88Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105612 to 12.488.25 to 13.2Fan reverse mounting support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC12V88Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105612 to 12.488.25 to 13.2Low speed fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC12V88Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105612 to 12.488.25 to 13.2Low leak current-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC12V88Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105612 to 12.488.25 to 13.2Instantaneous input voltage dip support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC15V70Fan for cooling / Parallel / Alarm OutputCE / UL / CUL / TUV / CSA61150240AC85 to 264/DC120 to 350105015 to 15.610.5–16.5NA-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC15V70Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105015 to 15.610.5–16.5NA-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC15V70Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105015 to 15.610.5–16.5Fan reverse mounting support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC15V70Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105015 to 15.610.5–16.5Low speed fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC15V70Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105015 to 15.610.5–16.5Instantaneous input voltage dip support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC15V70Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105015 to 15.610.5–16.5Long life fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC15V70Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105015 to 15.610.5–16.5Fan reverse mounting support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC15V70Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105015 to 15.610.5–16.5Low speed fan support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC15V70Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105015 to 15.610.5–16.5Low leak current-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC15V70Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105015 to 15.610.5–16.5Instantaneous input voltage dip support specifications-
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC24V44Fan for cooling / Parallel / Alarm OutputCE / UL / CUL / TUV / CSA61150240AC85 to 264/DC120 to 350105624 to 24.9616.5 to 26.4NA51A (AC input 200 V)
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC24V44Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105624 to 24.9616.5 to 26.4NA51A (AC input 200 V)
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC24V44Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105624 to 24.9616.5 to 26.4Long life fan support specifications51A (AC input 200 V)
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC24V44Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105624 to 24.9616.5 to 26.4Fan reverse mounting support specifications51A (AC input 200 V)
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC24V44Coating / Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105624 to 24.9616.5 to 26.4Low speed fan support specifications51A (AC input 200 V)
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC24V44Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105624 to 24.9616.5 to 26.4NA51A (AC input 200 V)
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC24V44Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105624 to 24.9616.5 to 26.4Long life fan support specifications51A (AC input 200 V)
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC24V44Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105624 to 24.9616.5 to 26.4Fan reverse mounting support specifications51A (AC input 200 V)
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC24V44Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105624 to 24.9616.5 to 26.4Low speed fan support specifications51A (AC input 200 V)
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC24V44Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105624 to 24.9616.5 to 26.4Low leak current51A (AC input 200 V)
26 Day(s) or more 10[With Cover] With Cover1000AC/DCDC24V44Fan for cooling / Parallel / Alarm Output-61150240AC85 to 264/DC120 to 350105624 to 24.9616.5 to 26.4Instantaneous input voltage dip support specifications51A (AC input 200 V)

Loading...

Basic Information

Single/multi Single Input/output terminal shape Terminal Block Excess current protective circuit Available
Excess voltage protective circuit Available Remote control Available Remote sensing Available

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7960 8499 / FAX:(60) 3 7960 7499
9:00am - 6:00pm (Monday - Friday)