Internal Wiring Vinyl Wire Flame Retardant UL cUL - UE/SSX1015 LF

Caution
Product Description
[Features]
- Uses both UL and cUL. (Category: AVLV2, AVLV8)
- UL VW-1 and cUL FT1 flame-retardant.
- Uses soft vinyl.
- The finely-wired conductor, features good flexibility and pliability.
- CE Marking Conformity Declaration Product (TUV certified product). (TUV Certificate No. J2050493)
Compliant standard
| Certification | UL AWM | cUL AWM | TUV.CE marking |
|---|---|---|---|
| Applicable standards | UL 758 | CSA C22.2 No.210 | EN50525-2-31 |
| Format symbol | UL STYLE 1015 | CSA AWM I A/B | Equivalent to H07V-K |
| Rated Voltage | 600 V | 600 V | 450/750 V |
| Rated temperature | 105°C | 105°C | 70°C |
| Conductor | UL 758 | CSA C22.2 No.210 | EN60228 |
| Flame Retardancy | VW-1 | FT1 | EN50264-2-1 |

Standard table

* In addition to the UL and CSA standard withstand voltage tests mentioned above, it has passed the 2,500 V / 5 min test.
* The allowable current value in the () is a reference value and for transport purpose only.
Product characteristics
Allowable current
- The allowable current is the value when single cable installed in air and the ambient temperature is 30°C.
- Multiply by the following correction factors according to the ambient temperatures, installation conditions, etc.
Current reduction coefficient (In case of ambient temperature)
| Ambient temperature (°C) | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
|---|---|---|---|---|---|---|---|---|
| Current reduction factor | 1.00 | 0.93 | 0.86 | 0.77 | 0.68 | 0.58 | 0.45 | 0.26 |
Current reduction coefficient (In the case of multi-row laying)
| Number of cables | 2 to 3 | 4 | 5 to 6 | 7 to 15 | 16 to 40 | 41 to 60 | 61 or more |
|---|---|---|---|---|---|---|---|
| Current reduction factor | 0.70 | 0.63 | 0.56 | 0.49 | 0.43 | 0.39 | 0.34 |
Transport property
| Bending | Winding | U-shaped folding | 90° flexing | Twisting | Transport bending | |
|---|---|---|---|---|---|---|
| Direct | Bending | |||||
| C | A | A | C | B | B | C |
Number of tests A = 10 million or more / B = 5 million or more / C = 3 million or more / D = 1 million or more / E = 500,000 or more
Oil resistance
| Insulation oil | Lubricant oil | Cutting oil I | Cutting oil II | Hydraulic oil | Grease |
|---|---|---|---|---|---|
| C | C | C | C | C | C |
* A to C in the table represent the following characteristics;
A: There is no practical problem at all. /B: There is little deterioration but almost no practical problem to use. /C: It shows a certain level of deterioration and may not be usable.
Wire core identification
Structural drawing

Surface printing

Identification
- Black, white, red, blue, Y/G
* The Y/G line is green with 3 yellow recessed color bands (30% to 50%).
Sales standard strip length
100 m