NC Relay

Caution
Product Description
Transistor drive 2c/4c 5A slim power relay
[Features]
· Flat type: height: 10.9 mm / Slim type: width: 11.2 mm
· Twin contacts
· Plug-in terminal / Printed circuit board terminal
· Sockets and terminal blocks are available
[Applications]
· Gas hot air heating equipment and air conditioners
· Timers and temperature control equipment
· Fax machines and electronic counting devices
· Machine tools, FA equipment and NC machinery
NC relay details

Product image of NC4 flat type printed circuit board terminal

Product image of NC2 flat type printed circuit board terminal

Product image of NC4 slim type plug-in terminal

Product image of NC2 slim type printed circuit board terminal
Specification example of NC relay
NC2D-DC6V
- Protective structure: Dust cover
- Terminal shape: Plug-In terminal
- Relay shape: Slim type
- Rated coil voltage: 6 V DC
- Rated power consumption: 360 mW
- Contact configuration: 2c
NC2D-DC100V
- Protective structure: Dust cover
- Terminal shape: Plug-In terminal
- Relay shape: Slim type
- Rated coil voltage: 100 V DC
- Rated power consumption: 740 mW
- Contact configuration: 2c
NC4D-DC6V
- Protective structure: Dust cover
- Terminal shape: Plug-In terminal
- Relay shape: Slim type
- Rated coil voltage: 6 V DC
- Rated power consumption: 720 mW
- Contact configuration: 4c
Coil rated
| Contact configuration | Rated coil voltage | Operate voltage * 1 (at 20°C) | Open voltage * 1 (at 20°C) | Rated operating current 〔±10%〕 (at 20°C) | Coil resistance 〔±10%〕 (at 20°C) | Rated power consumption | Maximum applied voltage (at 50°C) * 2 |
|---|---|---|---|---|---|---|---|
| 2c | 3 V DC | 80% V or less of rated coil voltage (Initial) | 10% V or more of rated coil voltage (Initial) | 120 mA | 25 Ω | 360 mW | 135% V of rated coil voltage |
| 5 V DC | 72 mA | 69.4 Ω | |||||
| 6 V DC | 60 mA | 100 Ω | |||||
| 12 V DC | 30 mA | 400 Ω | |||||
| 24 V DC | 15 mA | 1,600 Ω | |||||
| 48 V DC | 7.5 mA | 6,400 Ω | |||||
| 100 V DC | 7.4 mA | 13,500 Ω | 740 mW | 110% V of rated coil voltage | |||
| 4c | 3 V DC | 80% V or less of rated coil voltage (Initial) | 10% V or more of rated coil voltage (Initial) | 240 mA | 12.5 Ω | 720 mW | 110% V of rated coil voltage |
| 5 V DC | 144 mA | 34.7 Ω | |||||
| 6 V DC | 120 mA | 50 Ω | |||||
| 12 V DC | 60 mA | 200 Ω | |||||
| 24 V DC | 30 mA | 800 Ω | |||||
| 48 V DC | 15 mA | 3,200 Ω | |||||
| 100 V DC | 7.4 mA | 13,500 Ω | 740 mW |
- * 1 pulse drive: JIS C 5442
- * 2 plastic sealed: at 20°C
Performance overview
| Items | Performance overview | ||
|---|---|---|---|
| Contact rating | Contact configuration | 2c | 4c |
| Contact resistance (initial) | 50 mΩ or less (6 V DC 1 A by voltage drop method) | ||
| Contact Material | AgNi type + Au clad | ||
| Contact capacity (Resistant Load) | Dust cover: 5 A 250 V AC, 5 A 30 V DC Plastic sealed: 3 A 250 V AC, 5 A 30 V DC | Dust cover: 4 A 250 V AC, 5 A 30 V DC Plastic sealed: 2 A 250 V AC, 5 A 30 V DC | |
| Maximum allowable power for contacts (Resistant Load) | Dust cover: 1,250VA, 150 W Plastic sealed: 750VA, 150 W | Dust cover: 1,000VA, 150 W Plastic sealed: 500VA, 150 W | |
| Maximum allowable contact voltage | 250 V AC, 220 V DC | ||
| Maximum allowable current for contacts | Dust cover: 5 A (AC, DC) Plastic sealed: 3 A (AC), 5 A (DC) | Dust cover: 4 A (AC), 5 A (DC) Plastic sealed: 2 A (AC), 5 A (DC) | |
| Minimum applied load (Reference value) * 1 | 100μA 1 V DC | ||
| Insulation Resistance (Initial) | 100 MΩ or more (At 500 V DC ohmmeter, measured portion is the same as the case of withstand voltage) | ||
| Withstand Voltage (Initial) | Between open contacts | 1,000 V AC for 1 minute (Detection current: 10 mA) | |
| Between contact sets | 1,000 V AC for 1 minute (Detection current: 10 mA) | ||
| Between contact and coil | 2,000 V AC for 1 minute (Detection current: 10 mA) | ||
| Time characteristics (Initial) | Set time | 20 ms or less at rated coil voltage (at 20°C, without bounce) | |
| Reset time | 10 ms or less at rated coil voltage (at 20°C, without bounce, without diode) | ||
| Impact Resistance | Shock resistance (Functional) | 98 m/s^2 or more (half-sine shock pulse: 11 ms, detection time: 10 μs) | |
| Shock resistance (Destructive) | 980 m/s^2 or more (half-sine shock pulse: 6 ms) | ||
| Vibration resistance | Vibration resistance (Functional) | 10 to 55 Hz (Double amplitude: 1.0 mm, Detection time: 10 μs) | |
| Vibration resistance (Destructive) | 10 to 55 Hz (Double amplitude: 2.0 mm) | ||
| Open-close lifespan | Mechanical lifespan | 50 million times or more (Switching frequency: 180 times/minute) | |
| Usage conditions | Conditions of surroundings of use, transportation, storage | Temperature: -40 to +70°C (48 V DC or less), -40 to +55°C (100 V DC or more) Humidity: 5 to 85%RH (However, avoid icing and condensation) | Temperature: -40 to +55℃ Humidity: 5 to 85%RH (However, avoid icing and condensation) |
| Mass (weight) | Approx. 16 g | Slim type: Approximately 19 g, Flat type: Approx. 18 g | |
- * 1 This value is a rough indication of the lowest possible low level load at which switching is possible.
This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.
Dimensional example of NC relay
(Units: mm)

Dimensional drawing of flat type printed circuit board terminal 2c
(Units: mm)

Dimensional drawing of flat type printed circuit board terminal 4c
(Units: mm)

Dimensional drawing of flat type printed circuit board terminal 2c
(Units: mm)

Dimensional drawing of flat type printed circuit board terminal 4c
Tolerance
Under 1 mm: ±0.2
Under 1 to 3 mm: ±0.3
3 mm or more: ±0.5
Usage cautions
- * Since the NC relay is a polar relay, follow the instructions in the wiring diagram for the (+) (-) connection of the coil. If you make a mistake, it may cause a malfunction or it may not work.
- * In the case of NC relay, there is no problem in operation even if it is used with full wave current, but please note that the suction force will be slightly weakened and the vibration resistance and impact resistance will deteriorate.