Inner Dial Caliper Gauge

Features

●By replacing the attached replacement probe according to the measurement dimension, comparison measurement within ±1mm(specified range 2mm) of the set dimension can be performed. 
●Convenient to measure the groove diameter of the O ring by improving the r

Usage

●For comparative measurements such as the inner diameter of the cylindrical measuring object and the groove diameter of the inner part.

Specification

●Measurement Range(mm):20 to 35
●Instrument Error(mm):±0.02
●Minimum Display(mm):0.01
●Measurement Depth(mm):70
Part Number
IM-880
IM-881
IM-882
Part NumberVolume DiscountDays to ShipMaximum Measurement Length (Range Selection)
(mm)
Measuring Range
(mm)
Measurement depth
(mm)
Trusco Code Mass
(g)
Features Application
3 Day(s) or more 21~5020~3570272-0566196The use of included replaceable probes according to the measurement dimension enables the comparative measurement of the set dimension within ±1 mm (indicated range 2 mm). The improved (880 series) replaceable probe is useful in the measurement of the O-ring groove diameter. Offers the internal diameter measurement for the die cast sample.Comparative measurement for the inner diameter of cylindrical objects or the diameter of inner grooves.
3 Day(s) or more 51 to 10030~6275272-0574218The use of included replaceable probes according to the measurement dimension enables the comparative measurement of the set dimension within ±1 mm (indicated range 2 mm). The improved (880 series) replaceable probe is useful in the measurement of the O-ring groove diameter. Offers the internal diameter measurement for the die cast sample.Comparative measurement for the inner diameter of cylindrical objects or the diameter of inner grooves.
3 Day(s) or more 101~55~15390272-0582240The use of included replaceable probes according to the measurement dimension enables the comparative measurement of the set dimension within ±1 mm (indicated range 2 mm). The improved (880 series) replaceable probe is useful in the measurement of the O-ring groove diameter. Offers the internal diameter measurement for the die cast sample.Comparative measurement for the inner diameter of cylindrical objects or the diameter of inner grooves.

Loading...

  1. 1

Basic Information

Application Caliper Type Display Method Dial Scale interval minimal display(mm) 0.01
Scale type Continuous Scale Instrumental Error(mm) ±0.02 Minimum Display(mm) 0.01